Service Manual

HYDROSTATIC DRIVE SYSTEM
6-29Floating Deck Mid-Size Service Manual
6
Hydraulic Testing
Note: Cleanliness is a key factor in a successful
repair of any hydraulic system. Thoroughly
clean all exposed surfaces. As with any pre-
cision equipment, all parts must be kept free
of foreign material and chemicals. Protect all
exposed sealing areas and open cavities from
damage and foreign material.
The following procedure is performed on the left wheel
motor hydraulic hoses. It can also be performed from
several other locations on the machine.
When using a Bi-Directional Flow Test Kit, determining
directional ow is not necessary. The ow meter may
be connected in either direction into the forward and
reverse high pressure system lines.
Caution: Ensure all ttings and hoses are attached
securely. This test is performed on the machine’s
high pressure system. Failure to comply could result
in serious injury.
1. Apply the parking brake.
2. Loosen the 4 lug nuts (Fig. 1039).
3. Raise the rear of the machine and secure with jack
stands.
4. Release the parking brake.
5. Remove the 4 lug nuts and the wheel assembly (Fig.
1040).
Fig 1039 PICT-0373a
Fig 1040 PICT-0375
6. Thoroughly clean the area around the hydraulic
ttings to prevent debris from entering the system.
7. Mark the hoses and corresponding wheel motor
tting ports (Fig. 1041).
Fig 1041 PICT-0377