Operator's Manual

Special Tools
The following special tools are required for servicing the Order special tools from the
TORO SPECIAL TOOLS
HydroJect 3010.
AND APPLICATIONS GUIDE (COMMERCIAL
PRODUCTS)
.
Accumulator Charging Valve and Pressure Gauge - TOR4001 (Fig. 2)
The charging valve connects the accumulator to a high
pressure (3000-3500 or 6000 PSIG) Nitrogen tank for
pre-charging the accumulator. The charging valve can
also be used to measure accumulator pre-charge pres
-
sure without significant loss of accumulator pre-charge.
NOTE: The charging tool is equipped with a Com-
pressed Gas Association No. 677 tank connection.
5
6
1
4
2
3
Figure 2
1. Accumulator connector 4. Inlet valve
2. Pressure gauge 5. Relief valve
3. Outlet valve with diffuser 6. Nitrogen tank connector
Accumulator Seal Installation Tool - TOR4002 (Fig. 3)
Used for installing piston seal during accumulator
rebuilding.
Figure 3
Special Tools Page 6 - 4 HydroJect 3010