Service Manual

Table Of Contents
Groundsmaster 7200/7210 Page 5 - 7 Electrical System
Cutting Deck Operating P roblems
Problem Possible Causes
The cutting deck will not run with the PTO switch in the
ON (up) position.
The operator seat is unoccupied.
Oil level in hydraulic tank is low.
The seat switch or circuit wiring is faulty.
Wiring to the transmission PTO solenoid valve coil is
loose, corroded or damaged (see Chapter 8 - Foldout
Diagrams).
The transmission PTO solenoid valve coil is faulty.
The PTO switch is faulty.
Engine temperature is excessive (above 220
o
F/
105
o
C).
High temperature warning switch or circuit wiring is
faulty.
The Standard Control Module is faulty.
Transmission hydraulic solenoid valve is faulty (see
Chapter 4 - Hydraulic System).
PTO clutch in transmission is worn or damaged (see
Chapter 4 - Hydraulic System).
Transmission pressure valve or charge pump is faulty
(see Chapter 4 - Hydraulic System).
Electrical
System