Service Manual
Table Of Contents
- Title Page
- Revision History
- Reader Comments
- Preface
- Table Of Contents
- 1 - Safety
- 2 - Product Records and Maintenance
- 3 - Kubota Diesel Engine
- 4 - Hydraulic System
- Specifications
- General Information
- Hydraulic Schematics
- Hydraulic Flow Diagrams
- Special Tools
- Troubleshooting
- Testing
- Traction System Operation Testing
- Charge Relief Valve Pressure Test (Using Pressure Gauge)
- Transmission Piston Pump Flow Test (Using Tester with Pressure Gauges and Flow Meter)
- Traction Relief Valve Pressure Test (Using Tester with Pressure Gauges and Flow Meter)
- Wheel Motor Efficiency Test (Using Tester with Pressure Gauges and Flow Meter)
- PTO Pressure Valve Test (Using Pressure Gauge)
- Implement Relief Pressure Test (Using Pressure Gauge)
- Gear Pump Flow Test (Using Tester with Pressure Gauges and Flow Meter)
- Lift Cylinder Internal Leakage Test
- Service and Repairs
- General Precautions for Removing and Installing Hydraulic System Components
- Flush Hydraulic System
- Charge Hydraulic System
- Hydraulic Tank
- Wheel Motors
- Wheel Motor Service
- Transmission
- Transmission Service
- Gear Pump
- Gear Pump Service
- Manual Lift Control Valve (SN Below 313000000)
- Manual Lift Control Valve Service (SN Below 313000000)
- Lift Control Manifold (SN Above 313000000)
- Lift Control Manifold Service (SN Above 313000000)
- Polar TracTM Hydraulic Control Valve
- Polar TracTM Hydraulic Control Valve Service
- Lift Cylinder
- Lift Cylinder Service
- Polar TracTM Lift Cylinder
- Polar TracTM Lift Cylinder Service
- Oil Cooler
- 5 - Electrical System
- Electrical Schematics and Diagrams
- Special Tools
- Troubleshooting
- Electrical System Quick Checks
- Component Testing
- Ignition Switch
- Indicator Lights
- Hour Meter
- PTO Switch
- Neutral Switches
- Seat Switch
- Parking Brake Switch (SN Below 310000000)
- Parking Brake Switch (SN Above 310000000)
- Standard Control Module
- Standard Control Module Logic Chart
- PTO Solenoid Valve Coil
- Lift Control Manifold Solenoid Valve Coils (SN Above 313000000)
- Fusible Link Harness
- Diode Assembly
- Glow Relay
- High Temperature Warning Switch
- High Temperature Shutdown Switch
- Dual Temperature Switch (Polar TracTM Machines)
- Deck Lift/Lower Switch (SN Above 313000000)
- Fuel Pump
- Fuel Stop Solenoid
- Glow Controller
- Service and Repairs
- 6 - Chassis
- 7 - Cutting Deck
- 8 - Foldout Diagrams
- Electrical Drawing Designations
- Hydraulic Schematics
- Hydraulic Schematic (SN Below 313000000)
- Hydraulic Schematic (SN Below 313000000) with Rear Attach Lift Kit
- Hydraulic Schematic (SN Below 313000000) with Polar Trac Installed)
- Hydraulic Schematic (SN Below 313000000) with Polar Trac and Rear Attach Lift Kit
- Hydraulic Schematic (SN From 313000001 to 314999999)
- Hydraulic Schematic (SN Above 315000000)
- Electrical Schematics
- Circuit Diagrams
- Wire Harness
Groundsmaster 7200/7210Page 5 - 32Electrical System
Battery Storage
If the machine will be stored for more than 30 days:
1. Make sure ignition switch is in the OFF position. Re-
move the battery and charge it fully (see Battery Ser-
vice).
2. Either store battery on a shelf or on the machine.
3. Leave cables disconnected if the battery is stored on
the machine.
4. Store battery in a cool atmosphere to avoid quick de-
terioration of the battery charge.
5. To help prevent the battery from freezing during stor-
age, make sure it is fully charged (see Battery Service).
Battery Care
1. Battery electrolyte level must be properly main-
tained. The top of the battery must be kept clean. lf the
machine is stored in a location where temperatures are
extremely high, the battery will discharge more rapidly
than if the machine is stored in a location where temper-
atures are cool.
WARNING
Wear safety goggles and rubber gloves when
working with electrolyte. Charge battery in a
well ventilated place so gasses produced
while charging can dissipate. Since the gases
are explosive, keep open flames and electrical
sparks away from the battery; do not smoke.
Nausea may result if the gases are inhaled. Un -
plug charger from electrical outlet before con -
necting or disconnecting charger leads to or
from battery posts.
2. Keep top of battery clean by washing periodically
with a brush dipped in ammonia or bicarbonate of soda
solution. Flush top surface with water after cleaning. Do
not remove the fill caps while cleaning.
3. Battery cables must be tight on battery terminals to
provide good electrical contact.
WARNING
Connecting cables to the wrong post could re-
sult in personal injury and/or damage to the
electrical system.
4. If corrosion occurs at battery terminals, disconnect
cables. Always disconnect negative (- ) cable first.
Clean cable clamps and terminals separately. Recon-
nect cables with positive (+) cable first. Coat terminals
with battery terminal protector (Toro Part No. 107- 0392)
or a light coat of grease to reduce corrosion after con-
nections are made.
5. Check battery electrolyte level every 25 operating
hours and every 30 days if machine is in storage.
6. Maintain cell level with distilled or demineralized wa-
ter. Do not fill cells above the fill line.