Service Manual
Groundsmaster 4100−DPage 5 − 14Electrical System
Transport, Alarm Silence, and Temperature Override Switches
The transport, alarm silence, and temperature override
rocker switches are located on the control console (Fig.
18). These switches have common switching logic.
The switch terminals are marked as shown in Figure 19
and Figure 20. The circuitry of these switches is shown
in the chart below. With the use of a multimeter (ohms
setting), the switch functions may be tested to determine
whether continuity exists between the various terminals
for each position. Verify continuity between switch termi-
nals.
SWITCH
POSITION
NORMAL
CIRCUITS
OTHER
CIRCUITS
ON 2 + 3 5 + 6
OFF 1 + 2 4 + 5
NOTE: Terminals 7 (−) and 8 (+) on alarm silence and
temperature override switches are for the switch light.
1. Transport switch
2. Alarm silence switch
3. Temp. override switch
Figure 18
1
2
3
Figure 19
BACK OF TRANSPORT SWITCH
132
45 6
Figure 20
BACK OF ALARM SILENCE AND
132
45 6
8
7
TEMPERATURE OVERRIDE SWITCHES