Service Manual

Groundsmaster 4100--DHydraulic System Page 4 -- 34
TEST NO. 6: Cutting Deck Motor Case Drain Leakage (Using Tester with Pressure
Gauges and Flow Meter)
Working Pressure
Low (Charge) Pressure
Return or Suction
Flow
MEASURING
CONTAINER
TO LIFT/LOWER CONTROL VALVE
TO STEERING CONTROL VALVE
TRACTION
CIRCUIT
CHARGE CIRCUIT
CASE DRAIN/RETURN
NOTE: CENTER DECK MOTOR TEST SHOWN