Installation Instructions

3
InstallingtheSignalController
andHazardSwitch
Partsneededforthisprocedure:
1Turnsignalcontroller
1Decal,signal
1
Switch,hazard
1Wireharness,steeringtower
15
Cabletie
Procedure
1.Installtheturnsignalcontrollertothesteering
columnwiththeadjustableclampsuppliedwiththe
controller(
Figure3).
Figure3
1.Turnsignalcontroller3.Decal
2.Cabletie
2.Cleanthetopsurfaceoftheturnsignalcontroller.
3.Afxthesignaldecaltothetopoftheturnsignal
controller(
Figure3).
4.Installthehazardswitchintothetopofthesteering
column(Figure4).
Figure4
1.Hazardswitch
5.Locatethewireharnessunderthesteeringcover
openingintheoperator’splatform.
6.Plugtheconnectorbodyfromtheenclosedsteering
towerwireharnessintothewireharnessunderthe
steeringcoveropening.
7.Plugtheconnectorsfromthewireharnessintothe
connectorsfromtheashermodule,turnsignal
controllerandhazardswitch.
8.Securethewireharnesstothesteeringcolumnwith
the2cableties.
Note:Whenroutingthewires,ensurethatthe
operationofthetiltsteeringdoesnotdamagethe
harnessorpullonthewires.
3