Operator's Manual
ControlsSystem
Maintenance
AdjustingtheControlLever
NeutralInterlockSwitch
1.Stopthemachine,movethedeckliftswitchfullyinto
theneutral-lockedposition,settheparkingbrake,and
removetheignitionkey.
2.Removetheboltssecuringthefrontpanelandremove
thepanel(Figure56).
1
2
G020875
Figure56
1.Bolts
2.Controlpanel
3.Loosenthe2screwssecuringtheinterlockswitch
(Figure57).
Figure57
1.Controllever3.Screws
2.Neutralinterlockswitch
4.0.015to0.045inch(0.4to
1mm)
4.Holdingthecontrolleveragainsttheframe,movethe
switchtowardtheleveruntilthedistancebetweenlever
andswitchbodyis0.015to0.045inch(0.4to1mm)
(Figure57).
5.Securetheswitch.
6.Repeatsteps3to5fortheotherlever.
7.Installthefrontpanel.
50