Operator's Manual

2.Removethetemperaturesensorandgasket
fromtherearportofthewaterpump(Figure23).
Note:Retainthetemperaturesensorfor
installationinstep5.
g233715
Figure23
1.Temperaturesensor(old)4.Forwardport(water-pump
housing)
2.Gasket(temperature
sensor)
5.Gasket(plug)
3.Rearport(water-pump
housing)
6.Plug
3.Removetheplugandgasketfromtheforward
portofthewaterpump(Figure23).
Note:Younolongerneedtheplugandgasket.
4.Installthereducerandthegasket(plug)intothe
forwardportofthewaterpump(Figure24).
g233712
Figure24
1.Reducer
3.Forwardport(water-pump
housing)
2.O-ring
4.Temperaturesensor
5.ApplyPTFEthreadsealanttothethreadsofthe
temperaturesensorthatyouremovedinstep2
andtothethreadsofthestraightbarbedtting.
6.Installthenewtemperaturesensorintothe
reducer(Figure24).
7.Installthebarbedttingintotherearportofthe
water-pumphousing(Figure25)andtightenthe
tting2to3turnsbeyondngertight.
16