Service Manual

ELECTRICAL
9-4 Fixed Deck Mid-Size Service Manual
9
Fig 1167 diag 1
SW1
PTO Switch
SW2
Operator Presence Switch
KAWASAKI TWIN
PTO Switch closes
when blade is engaged
Switch closed when
operator is not present
SW3
Ignition Switch
Switch open
when on
BK BU W
BK
W
GND
BK
W
MAG
WIRE COLOR CODES
BK Black W White
BU Blue
Spark
Plug
Spark Plug
Ignition
Modules
This is the most basic system. It grounds the magneto
through two circuits.
PTO
Switch
Operator
Presence
Switch
Ignition
Switch
Engine
Open Open Open has spark
Closed Open Open has spark
Closed Closed Open no spark
Open Open Closed no spark
Open Closed Open has spark
One circuit is the ignition switch and the other contanis
the PTO and Operator Presence switch. Both circuits
must be open for the engine to start or run.
The xed deck midsize mowers use three different
electrical systems. All are intended to ensure a safe
condition when starting and prevent the operator from
leaving the operator zone with the machine in an unsafe
condition. The difference in the systems is due to the
type of controls on each model.
Electrical Systems
Gear Drive T-Bar