Operator's Manual
Figure19
1.Fueltankcap2.Fuelgauge
4.Fillthetankuntilthelevelistothebottomoftheller
neckwithdieselfuel.
5.Installfueltankcaptightlyafterllingtank.
Note:Ifpossible,llthefueltankaftereachuse.This
willminimizepossiblebuildupofcondensationinside
thefueltank.
CheckingtheHydraulicFluid
Themachinesreservoirislledatthefactorywith
approximately10U.S.gallons(37.8l)ofhighqualityhydraulic
uid.Checkthelevelofthehydraulicuidbeforethe
engineisrststartedanddailythereafter.Therecommended
replacementuidisasfollows:
ToroPremiumAllSeasonHydraulicFluid(Availablein5
gallonpailsor55gallondrums.SeepartscatalogorT oro
distributorforpartnumbers.)
Alternateuids:IftheTorouidisnotavailable,other
uidsmaybeusedprovidedtheymeetallthefollowing
materialpropertiesandindustryspecications.Wedonot
recommendtheuseofsyntheticuid.Consultwithyour
lubricantdistributortoidentifyasatisfactoryproductNote:
Torowillnotassumeresponsibilityfordamagecausedby
impropersubstitutions,souseonlyproductsfromreputable
manufacturerswhowillstandbehindtheirrecommendation.
HighViscosityIndex/LowPourPointAnti-wearHydraulic
Fluid,ISOVG46
MaterialProperties:
Viscosity,ASTMD445cSt@40°C44to48cSt
@100°C7.9to8.5
ViscosityIndexASTM
D2270
140to160
PourPoint,ASTMD97-34°Fto-49°F
IndustrySpecications:
VickersI-286-S(QualityLevel),VickersM-2950-S
(QualityLevel),DenisonHF-0
Note:Manyhydraulicuidsarealmostcolorless,makingit
difculttospotleaks.Areddyeadditiveforthehydraulic
systemoilisavailablein2/3oz.(20ml)bottles.Onebottleis
sufcientfor4-6gal(15-221)ofhydraulicoil.Orderpartno.
44-2500fromyourauthorizedTorodistributor.
BiodegradableHydraulicFluid-Mobil224H
ToroBiodegradableHydraulicFluid(Availablein5
gallonpailsor55gallondrums.SeepartscatalogorT oro
distributorforpartnumbers.)
Alternateuid:MobilEAL224H
Note:Thisisvegetable-oilbasedbiodegradableoiltested
andapprovedbyToroforthismodel.Thisuidisnotas
resistanttohightemperaturesasstandarduid,sobesure
tofollowtherecommendeduidchangeintervalswiththis
uid.Contaminationbymineral-basedhydraulicuidswill
changethebiodegradabilityandtoxicityofthisoil.When
changingfromstandarduidtothebiodegradabletype,be
certaintofollowtheapprovedushingprocedure.Contact
yourlocalToroDistributorfordetails.
1.Positionmachineonalevelsurface,lowerthecutting
decksandstoptheengine.
2.Cleanareaaroundllerneckandcapofhydraulictank
(Figure20).
Figure20
1.Hydraulictankcap
3.Removecap/dipstickfromllerneckandwipeitwith
acleanrag.Insertdipstickintollerneck;thenremove
itandchecklevelofuid.Fluidlevelshouldbewithin
operatingrangeondipstick.Donotoverll.
4.Iflevelislow,addappropriateuidtoraiselevelto
fullmark.
5.Installcap/dipstickontollerneck.
22