Groundsmaster 4300 Diagnostic Fault Code Quick Reference Table Page 1 of 4
GM 4300 DIAGNOSTIC FAULT CODE QUICK REFERENCE TABLE
Fault
Number
Fault Title
Controller
Affected
Fault Condition/Circuit
Description
Additional Notes
Service Actions
1
Engine Coolant
Temp PTO Kill
Master
This fault is reported when the
engine coolant temperature has
reached 105 °C (220 °F).
PTO will be disabled
1) Test the cooling fan function.
2) Inspect the airflow passages.
3) Check the coolant level.
2
Engine Coolant
Temp Engine Kill
Master
This fault is reported when the
engine coolant temperature has
reached 115 °C (240 °F).
Engine will be shut
down
1) Test the cooling fan function.
2) Inspect the airflow passages.
3) Check the coolant level.
3
Fuse Failure
Master
This fault is reported when the
fuse is blown on one of the
output circuits on the master
TEC.
1) Check 7.5 amp fuse F2-1
protecting outputs 14 on the
master TEC.
2) Check 7.5 amp fuse F2-2
protecting outputs 58 on the
master TEC.
3) Check 7.5 amp fuse F23
protecting outputs 912 on the
master TEC.
4
IPE Voltage Too
Low
Master
This fault is reported when the
inputs or outputs on the master
TEC are not working correctly.
This is an internal
circuit board fault
inside the master TEC.
1) Replace the master TEC
controller.
5
Main Power Relay
Failure
Master
This fault is reported when the
main power relay on the master
TEC has failed.
1) Test all of the 7.5 amp fuses.
2) Test the function of the main
power relay.
3) Ensure that the master TEC is
getting 12 Vdc from the relay.
6
Key Start Timeout
Master
This fault is reported when the
ignition key has been stuck or
held in the Start position for
more than 30 seconds.
If the key was being
held for more than 30
seconds, returning key
to the “Run” position
will clear the fault.
1) Check the ignition key switch
function.
2) Check all connections for
corrosion.
7
Software
Incompatible
Master
This fault is reported when either
the machine model number is not
valid, or the master TEC
controller received a message
from another master TEC
controller on the bus circuit.
1) Reprogram the machine using
Toro DIAG.