Operator's Manual
g031878
g031863
Figure79
ChangingtheHydraulic
Fluid
ServiceInterval:Every800hours
Iftheuidbecomescontaminated,contactyourT oro
Distributorbecausethesystemmustbeushed.
Contaminateduidlooksmilkyorblackwhen
comparedtocleanoil.
1.TurnthekeyintheignitionswitchtotheOFF
positionandraisethehood.
2.Disconnectthecasereturnlinefromthebottom
ofthereservoirandletthehydraulicuidow
intoalargedrainpan.
3.Installthehosewhenthehydraulicuidstops
draining.
4.Fillthereservoirwithapproximately28.4L(7.50
USgallons)ofhydraulicuid;refertoChecking
theHydraulic-FluidLevel(page59).
Important:Useonlythehydraulicuids
specied.Otheruidscouldcausesystem
damage.
5.Installthereservoircap.
6.TurnthekeyintheignitionswitchtotheON
positiontostarttheengine,useallofthe
hydrauliccontrolstodistributehydraulicuid
throughoutthesystem,andcheckforleaks.
7.TurnthekeyintheignitionswitchtotheOFF
position.
8.Checktheuidlevelandaddenoughtoraise
leveltheleveltotheFULLmarkonthedipstick.
Donotoverll.
60