Operator's Manual

andtheenginewillnotstart;refertoBleedingtheFuel
System.
1.LoosenthepipeconnectiontotheNo.1nozzleand
holderassembly(Figure38).
Figure38
1.Fuelinjectors
2.TurnthekeyinthekeyswitchtotheOnpositionand
watchthefuelowaroundtheconnector.Whenyou
observeasolidowoffuel,turnthekeytotheOff
position.
3.Tightenthepipeconnectorsecurely.
4.Repeatsteps1through3ontheremainingnozzles.
CleaningtheFuelTank
ServiceInterval:Every2years
Drainandcleanfueltankevery2years.Also,removeand
cleanthein-linestrainersafterdrainingthetank.Useclean
dieselfueltoushoutthetank.
Important:Drainandcleanthetankifthefuelsystem
becomescontaminatedorifthemachineistobestored
foranextendedperiod.
FuelLinesandConnections
ServiceInterval:Every400hours
Checkthefuellinesandconnectionsevery400hoursor
yearly,whichevercomesrst.Inspectthemfordeterioration,
damage,chafng,orlooseconnections.
37