Service Manual

Groundsmaster 360Page 5 − 8Electrical System
(Rev. A)
Fault Code (Lamp Flashes)
Fault Description
1 − 1 High engine temp warning occurred (PTO was shutdown by controller)
1 − 2 High engine temp shutdown occurred (engine was shutdown by controller)
1 − 3 Low engine oil pressure occurred
1 − 4 Engine alternator fault occurred
1 − 5 Charging voltage was out of acceptable range
2 − 1 Upper fuse 3 (7.5 amp) for TEC outputs is faulty
2 − 2 Upper fuse 2 (7.5 amp) for TEC outputs is faulty
2 − 3 Upper fuse 1 (7.5 amp) for TEC outputs is faulty
2 − 4 No power available to TEC outputs (e.g. all fuses or main power relay faulty)
3 − 1 Current output to start relay was excessive (shorted or grounded)
3 − 2 Current output to run relay was excessive (shorted or grounded)
3 − 3 Current output to glow relay was excessive (shorted or grounded)
3 − 4 Current output to diagnostic light was excessive (shorted or grounded)
3 − 5 Current to PTO solenoid was excessive (shorted or grounded)
4 − 1 Current output to indicator light in steering selector switch circuit was excessive
(shorted or grounded)
4 − 2 Current output to deck raise circuit was excessive (shorted or grounded)
4 − 3 Current output to deck float circuit was excessive (shorted or grounded)
4 − 4 Current output to 4 wheel steer solenoid was excessive (shorted or grounded)