Service Manual

Section
10.
Starting
WARNING
Incorrect service or replacement of
parts
can result in severe personal injury and/or
equlpment damage. Service personal must
be
qualified to
perform
electrical and/or mechanl-
cal service
WARNING
Accidental starting of the englne
can result In severe personal Injury or death.
Disconnect the negative
(-)
battery cable and
spark
plug
wife before serviclng the englne,
controls, or associated equlpment.
RECOIL
STARTER
Disassembly:
Refer to Figure
10-1.
Remove the
four capscrews holding the recoil assembly on the
engine. Remove the recoil assembly from the
blower housing.
Inspection/Service
Inspect the assembly as a
unit. The
rope
should pull out freely with spring ten-
sion, pulling the
rope
back in without binding or
slack. When pulling the rope
out,
the
dog
ears
should come out of their cup and they should not
be
bent, broken, or missing.
Assembly;
Place the recoil assembly on the blower
housing. Install and torque the four capscrews to
the torque specified in
Assembly
Torques.
CAP
SCREW
RECOIL
ASSEMBLY
M-1811
FIGURE
10-1.
RECOIL STARTER REMOVAL
110
VAC STARTER
Disassembly:
Refer to Figure
10-2.
Remove the
two
drive cap mounting screws and remove the as-
sembly from the engine.
Inspection/Servlce:
Replace the entire plug/
switch/motor assembly
if
the motor does not oper-
ate or is not strong enough to turn the engine. Re-
place the pinion gear and associated parts
if
the pin-
ion is worn and/or binds on the shaft. The parts are
available in kit form. Follow the kit instructions.
If
the
drive cap bearing appears worn, replace the drive
cap.
a
PLUG/
SWITCH/MOTOR
ASSEMBLY
DRIVE
CAP
FIGURE
10-2.110
VAC STARTER
10-1