Operator's Manual
MaintenanceService
Interval
MaintenanceProcedure
Every250hours
•Replacetheprimaryair-cleanerelement(moreofteninextremelydustyorsandy
conditions).
•Checkthesecondaryair-cleanerelement(moreofteninextremelydustyorsandy
conditions).
•Changetheauxiliaryhydraulicreservoirlteranduid.
•Changethetransmissionlters.
•Fillthetransmissionwithuidwhenchangingthelter.
Every500hours
•Replacethesecondaryair-cleanerelement(moreofteninextremelydustyorsandy
conditions).
Every800hours
•Replacethefuellter.
Yearly
•Greasethefrontcasterpivots.
•Greasethebeltidlerpivot.
•Greasethecasterpivotsandhubs.
•Lubricatethecaster-wheelhubs.
•Lubricatethecaster-wheelhubs.
•Checkthetorqueofthewheelhubnuts.
•Checkthetorqueonthewheellugnuts.
•Checkthetorqueofthetransmissionoutputshaftnut.
Yearlyorbeforestorage
•T ouchupareaswithchippedpaint.
Pre-Maintenance
Procedures
CAUTION
Raisingthemachineforserviceor
maintenancerelyingsolelyonmechanical
orhydraulicjackscouldbedangerous.The
mechanicalorhydraulicjacksmaynotbe
enoughsupportormaymalfunctionallowing
themachinetofall,whichcouldcauseinjury.
Donotrelysolelyonmechanicalorhydraulic
jacksforsupport.Useadequatejackstands
orequivalentsupport.
PreparingfortheMachine
forMaintenance
Performthefollowingbeforeservicing,cleaning,or
makinganyadjustmentstothemachine.
1.Parkthemachineonalevelsurface.
2.Shutofftheengine,engagetheparkingbrake,
waitforallmovingpartstostop.
3.Removethekeyfromthekeyswitch.
AccessingtheConsole
Compartment
RemovingtheConsolePad
1.Loosenthe4anged-headboltsthatsecurethe
padtotheleftandrightconsolepanels(Figure
25).
g025880
Figure25
1.Keyholeslot(console
panel)
3.Pad
2.Fanged-headbolt
2.Liftuptheconsolepad(Figure25)approximately
13mm(1/2inch).
3.Pulltheconsolepadstraightbackandremove
thepadfromthemachine(Figure25).
29