Operator's Manual
CheckingandAdjustingthe
TractionCable
ServiceInterval:Aftertherst2hours—Inspectthe
tractioncableandadjustitifnecessary.
Yearly—Inspectthetractioncableandadjustor
replaceitifnecessary.
Ifthemachinedoesnotdriveintheforwardorreversespeeds
oritdriveswhenyoureleasethetractionlever,adjustthe
tractioncable.
Iftheleft(traction)cableisnotproperlyadjusted,dothe
followingsteps:
1.Loosenthejamnut.
2.Engagethetractionleverandholditinplace(Figure
36).
Figure36
3.Loosenortightentheturnbuckletoadjustspring
lengthto5.5cm(2.18inches)(Figure37).
Figure37
1.Jamnut
3.Spring
2.Turnbuckle
4.5.5cm(2.18inches)
4.Tightenthejamnut(Figure37),ensuringthereisslight
tensiononthecable.
5.Ifthetractioncableisproperlyadjustedbutaproblem
remains,contactanAuthorizedServiceDealer.
CheckingandAdjustingthe
Auger/ImpellerCable
ServiceInterval:Aftertherst2hours—Inspectthe
auger/impellercableandadjustitif
necessary.
Yearly—Inspecttheauger/impellercableandadjust
orreplaceitifnecessary.
1.Loosenthejamnut.
2.Engagetheauger/impellerleverandholditinplace
(Figure38).
Figure38
3.Loosenortightentheturnbuckletoadjustthespring
lengthto7cm(2.75inches)asshowninFigure39.
Figure39
1.Jamnut
3.Spring
2.Turnbuckle
4.7cm(2.75inches)
4.Tightenthejamnut(Figure39),ensuringthereisslight
tensiononthecable.
19