Operator's Manual

Figure48
1.0.030inch(0.76mm)
5.Installthenewsparkplug,tightenitrmly,andattach
theignitionwiretothesparkplug.
Note:Ensuretheignitionwiresnapscompletelyinto
placeonthesparkplug.
AdjustingtheDischargeChute
Latch
Ifthedischargechutedoesnotlockintothedesiredposition
ordoesnotunlocksothatyoucanmoveittoanother
position,adjustthedischargechutelatch.
1.Loosentheclampfasteneronthechutesupportplate
untilthecableisfree.
g019021
1
2
3
Figure49
1.Cableconduit3.Clampfastener
2.Cableclamp
2.Removeanyslackinthecablebypullingthecable
conduitrearward.
3.Tightentheclampfastenerwhileholdingthecablein
place.
ReplacingtheDriveBelts
Iftheauger/impellerdrivebeltorthetractiondrivebelt
becomesworn,oil-soaked,orotherwisedamaged,havean
AuthorizedServiceDealerreplacethebelt.
24