Use and Care Manual

CheckingandAdjustingthe
Auger/ImpellerCable
ServiceInterval:Aftertherst2hours—Inspectthe
auger/impellercableandadjustitif
necessary.
Yearly—Inspecttheauger/impellercableand
adjustorreplaceitifnecessary.
1.Loosenthejamnut.
2.Engagetheauger/impellerleverandholditin
place(Figure33).
g001013
Figure33
3.Loosenortightentheturnbuckletoadjustthe
springlengthto7cm(2-3/4inches)asshown
inFigure34.
g031000
Figure34
1.Jamnut
3.Spring
2.Turnbuckle
4.7cm(2-3/4inches)
4.Tightenthejamnut(Figure34),ensuringthat
thereisslighttensiononthecable.
5.Iftheauger/impellercableisproperlyadjusted
butaproblemremains,contactanAuthorized
ServiceDealer.
Checkingthe
Auger-Gearbox-OilLevel
ServiceInterval:Yearly—Checktheauger-gearbox
oilandaddoilifnecessary.
1.Movethemachinetoalevelsurface.
2.Cleantheareaaroundthepipeplug(Figure35).
g001025
Figure35
1.Pipeplug
3.Removethepipeplugfromthegearbox.
4.Checktheoillevelinthegearbox.Theoilshould
be9.5mm(3/8inch)belowthelleropening.
5.Iftheoillevelislow,addGL-5orGL-6,SAE
80-90EPgearoillubricanttothegearboxuntil
theoillevelis9.5mm(3/8inch)belowtheller
opening.
Note:Donotusesyntheticoil.
6.Installthepipepluginthegearbox.
20