Use and Care Manual

CheckingandAdjustingthe
TractionCable
ServiceInterval:Aftertherst2hours—Inspect
thetractioncableandadjustitif
necessary.
Yearly—Inspectthetractioncableandadjustor
replaceitifnecessary.
Ifthemachinedoesnotdriveintheforwardorreverse
speedsoritdriveswhenyoureleasethetractionlever,
adjustthetractioncable.
Iftheleft(traction)cableisnotproperlyadjusted,do
thefollowingsteps:
1.Loosenthejamnut.
2.Engagethetractionleverandholditinplace
(Figure32).
g001011
Figure32
3.Loosenortightentheturnbuckletoadjustthe
springlengthto5.5cm(2.18inches)asshown
inFigure33.
g030998
Figure33
1.Jamnut
3.Spring
2.Turnbuckle
4.5.5cm(2.18inches)
4.Tightenthejamnut(Figure33),ensuringthere
isslighttensiononthecable.
5.Ifthetractioncableisproperlyadjustedbuta
problemremains,contactanAuthorizedService
Dealer.
CheckingandAdjustingthe
Auger/ImpellerCable
ServiceInterval:Aftertherst2hours—Inspectthe
auger/impellercableandadjustitif
necessary.
Yearly—Inspecttheauger/impellercableand
adjustorreplaceitifnecessary.
1.Loosenthejamnut.
2.Engagetheauger/impellerleverandholditin
place(Figure34).
g001013
Figure34
18