Operator's Manual

CheckingandAdjustingthe
TractionCable
ServiceInterval:Aftertherst2hours—Inspect
thetractioncableandadjustitif
necessary.
Yearly—Inspectthetractioncableandadjustor
replaceitifnecessary.
Ifthemachinedoesnotdriveintheforwardorreverse
speedsoritdriveswhenyoureleasethetractionlever,
adjustthetractioncable.
Iftheleft(traction)cableisnotproperlyadjusted,do
thefollowingsteps:
1.Loosenthejamnut.
2.Engagethetractionleverandholditinplace
(Figure26).
g001011
Figure26
3.Loosenortightentheturnbuckletoadjustthe
springlengthto5.5cm(2–3/16inches)as
showninFigure27.
g030998
Figure27
1.Jamnut
3.Spring
2.Turnbuckle
4.5.5cm(2–3/16inches)
4.Tightenthejamnut(Figure27),ensuringthat
thereisslighttensiononthecable.
5.Ifthetractioncableisproperlyadjustedbuta
problemremains,contactanAuthorizedService
Dealer.
CheckingandAdjustingthe
Auger/ImpellerCable
ServiceInterval:Aftertherst2hours—Inspectthe
auger/impellercableandadjustitif
necessary.
Yearly—Inspecttheauger/impellercableand
adjustorreplaceitifnecessary.
1.Loosenthejamnut.
2.Engagetheauger/impellerleverandholditin
place(Figure28).
g001013
Figure28
21