Use and Care Manual

g001569
Figure42
1.Tab
2.1.5mm(1/16inch)
4.Iftheauger/impellercableisnotproperly
adjusted,dothefollowingsteps:
5.Loosenthejamnut(Figure43).
g001024
Figure43
1.Jamnut2.Turnbuckle
6.Loosenortightentheturnbucklethatadjuststhe
tensiononthecable(Figure43).
7.Adjusttheturnbuckleuntilyouobtaintheproper
gap.
8.Tightenthejamnut.
9.Insertthe2screwsthatyoupreviouslyremoved
onthebeltcover.
10.Iftheauger/impellercableisproperlyadjusted
butaproblemremains,contactanAuthorized
ServiceDealer.
Checkingthe
Auger-Gearbox-OilLevel
ServiceInterval:Yearly—Checktheauger-gearbox
oilandaddoilifnecessary.
1.Movethemachinetoalevelsurface.
2.Cleantheareaaroundthepipeplug(Figure44).
g016782
Figure44
1.Pipeplug
3.Removethepipeplugfromthegearbox.
4.Checktheoillevelinthegearbox.Theoilshould
beatthepointofoverowingatthelleropening.
5.Iftheoillevelislow,addGL-5orGL-6,SAE
85-95EPgearoillubricanttothegearboxuntil
thepointofoverow.
Note:Donotusesyntheticoil.
6.Installthepipepluginthegearbox.
ChangingtheEngineOil
ServiceInterval:Aftertherst5hours—Changethe
engineoil.
Every50hours—Changetheengineoil.
Changetheengineoilevery25operatinghours
whenoperatingtheengineunderaheavyload.
Ifpossible,runtheengineforafewminutesbefore
changingtheoilbecausewarmoilowsbetterand
carriesmorecontaminants.
EngineoilcapacityModels38801and38802:
0.89to0.95L(30to32oz)
OilviscosityRefertoFigure39.
APIserviceclassicationSJorhigher
UseFigure45belowtoselectthebestoilviscosityfor
theoutdoortemperaturerangeexpected:
21