Operator's Manual

CheckingandAdjustingthe
Auger/ImpellerCable
ServiceInterval:Aftertherst2hours—Inspectthe
auger/impellercableandadjustitif
necessary.
Yearly—Inspecttheauger/impellercableand
adjustorreplaceitifnecessary.
1.Removethe2screwsthatareholdingthebelt
coverinplace(Figure25).
2.Removethebeltcover(Figure25).
g260066
Figure25
3.Withtheauger/impellerleverdisengaged,
ensurethatthegapbetweentheaugerclutch
armandtheframeofthemachineis1.5mm
(1/16inch)asshowninFigure26.
g260108
Figure26
1.1.5mm(1/16inch)
3.Augerclutcharm
2.Frame
4.Iftheauger/impellercableisnotproperly
adjusted,dothefollowingsteps:
5.Loosenthejamnut(Figure27).
g260109
Figure27
1.Jamnut2.Turnbuckle
6.Loosenortightentheturnbucklethatadjuststhe
tensiononthecable(Figure27).
7.Adjusttheturnbuckleuntilyouobtaintheproper
gap.
8.Tightenthejamnut.
9.Insertthe2screwsthatyoupreviouslyremoved
onthebeltcover.
10.Iftheauger/impellercableisproperlyadjusted
butaproblemremains,contactanAuthorized
ServiceDealer.
Checkingthe
Auger-Gearbox-OilLevel
ServiceInterval:Yearly—Checktheauger-gearbox
oilandaddoilifnecessary.
1.Movethemachinetoalevelsurface.
2.Cleantheareaaroundthepipeplugandremove
thepipeplugfromthegearbox(Figure28).
Note:Ifneeded,useplierstoassistinremoving
thepipeplug.
19