Use and Care Manual

CheckingandAdjustingthe
Auger/ImpellerCable
ServiceInterval:Aftertherst2hours—Inspectthe
auger/impellercableandadjustitif
necessary.
Yearly—Inspecttheauger/impellercableand
adjustorreplaceitifnecessary.
1.Loosenthejamnut(Figure31).
2.Engagetheauger/impellerleverandholditin
place(Figure30).
g360687
Figure30
3.Loosenortightentheturnbuckletoadjustthe
springlengthto7cm(2-3/4inches)asshown
inFigure31.
g031000
Figure31
1.Jamnut
3.Spring
2.Turnbuckle
4.7cm(2-3/4inches)
4.Tightenthejamnut(Figure31),ensuringthat
thereisslighttensiononthecable.
5.Turnonthemachineandattempttoengagethe
auger/impellerdrivewithoutmovingthelock
switchback;iftheaugerrotates,loosenthe
turnbucklesothattheaugerdoesnotengage.
6.Iftheauger/impellercableisproperlyadjusted
butaproblemremains,contactanAuthorized
ServiceDealer.
26