Operator's Manual

6
Maintenance
Greasing the Sprayer
Lubricate the boom extension bearings after every
100 hours or once a year, whichever occurs first. Refer to
Greasing the Pivot Arms, page 4, for more information.
Stowing the Boom Extensions
Use the boom restraints to lock the boom extensions in the
X position when you are not spraying.
Note: If you have the Workman spray system, the left
boom holder holds the left boom and the right boom holder
holds the right boom.
1. Pivot the left boom extension into the upright position.
Important Do not force the boom extension past the
restraint hook when stowing or you may damage the
extension and nozzles.
2. Push up on the right restraint knob to compress the
spring and extend the hook.
3. With the spring compressed, rotate the hook to catch the
boom extension frame.
4. Release the knob allowing the hook to catch the boom
extension frame and secure it to the boom holder.
5. Repeat steps 1-4 with the right boom extension and left
boom holder.