Operator's Manual

12
BEFORE SPRAYING
After all installation procedures have been
completed, boom bypass valves closed, and
Console power is turned "ON", the Console will
flash "CAL" and "US VOLUME PER ACRE". This
means you must calibrate or program the Console
before it can be operated.
NOTE: Turning the POWER ON/OFF switch to
"OFF", or disconnecting Console cables does
not affect the Console memory. All data is
retained.
While the calibration figures shown below are
useful guidelines, calculations should be carried
out for your particular machine and refined to
accommodate carrying operating conditions and
desired applications.
DATA ENTRY
When entering data into the consoles, the entry
sequence is always the same. (NOTE: DATA
MUST BE ENTERED INTO THE FIRST EIGHT
KEYS).
1. Depress the key in which you wish to enter
data.
2. Depress the "ENTER" key. An "E" will illuminate
in the data DISPLAY.
3. Depress the keys corresponding to the number
you wish to enter (i.e. "1", "0", "2", "4"). The numbers
will be displayed in the DATA display as they are
entered.
4. Complete the entry by again depressing the
"ENTER" key.
INITIAL CONSOLE PROGRAMMING:
If an entry selection error is made during the
next four steps, the Console can be reset by
turning the Console off and, while depressing
CE
, turn Console back on. Display will show
"CAL" and "US Volume Per Acre".
1. Display US (volume per acres), SI (volume per
hectares), or TU (volume per 1000 sq. ft.).
a. Depressing momentarily
CE
steps the
DATA display from US - Volume per Acre to SI -
Volume per Hectare.
b. Depressing momentarily
CE
steps the
DATA display from SI - Volume per Hectare to TU
- Volume per 1000 Sq. Ft.
c. Depressing momentarily
CE
steps the
DATA display from TU - Volume per 1000 Sq. Ft.
to US - Volume per Acre.
2. Selecting US, SI or TU.
a. To select US, SI or TU, Depress
CE
until the desired code is displayed in DATA display.
b. Momentarily depress
ENTER
. The DATA
display will now display SP1 - Wheel Drive.
3. Display SP1 - Wheel Drive, SP2 - Radar Speed
Drive, SP3 - Gear Tooth Drive (Toro Multi Pro
®
5600
Pro-Control
)
.
a. Depressing momentarily
CE
steps the
DATA display from SP1 - Wheel Drive to SP2 -
Radar Speed Drive.
b. Depressing momentarily steps the
DATA display from SP2 - Radar Speed Drive to
SP3 - Gear Tooth Drive.
4. Selecting SP1, SP2, and SP3.
a. To select SP1, SP2, and SP3 step with
CE
until SP3 is displayed in DATA display.
b. Momentarily depress
ENTER
the DATA
display will now display 0.
5. Enter BOOM 1 CAL (80) in key labeled:
BOOM1
CAL
1
6. Enter BOOM 2 CAL (60) in key labeled:
BOOM2
CAL
2
7. Enter BOOM 3 CAL (80) in key labeled:
BOOM3
CAL
3
8. Enter SPEED CAL (148) in key labeled:
SPEED
CAL
4
9. Enter METER CAL calibration number in key
labeled:
METER
CAL
5
(METER CAL Number is located on
Flow Meter).
10. Enter VALVE CAL calibration number (023) in
key labeled:
VALVE
CAL
6
(Note - for Yellow Nozzles at low
rates use 043 or 063).
11. Enter the Application Target Rate in gallons
per acre, liters per hectare, gallons per 1000 sq.
ft. that you want to spray in the key labeled:
RATE1
CAL
7
12. Enter a second target application rate in
gallons per acre, liters per hectare or gallons per
1000 sq. ft. that you want to spray in key
labeled:
RATE2
CAL
8
if desired.
CE