Operator's Manual

15
11. Turn MAN/RATE switch to "RATE 1". The Pump
should increase pressure until desired rate is
achieved.
12. Turn the Boom switches off. The system will
stop the Pump.
13. The Pro-Control System is designed to
regulate Agitation pressure automatically. The Pro-
Control is pre-programmed and will provide
Agitation pressure with the Spray Booms turned
Off. However, the pre-programmed Agitation
should be tested and modified, if needed, per the
following procedure.
Turn the Agitation switch ON. The System will start
the Pump and Increase Pump speed until the
Preset Agitation pressure is achieved. The System
goes to this pressure anytime the Booms are Off
and the Pump and Agitation Switch are On.
If your Preset Agitation is at a pressure you deam
acceptable (we recommend 40 to 60 psi), no
programming is required.
If you would like to change your Preset Agitation
pressure, press the
DA TA
MENU
button. Preset Agitation
80 will be displayed. Increase or Decrease the
Preset Agitation value by increments of 5 until the
pressure is close to what you desire. Then
Increase or Decrease by increments of 1 until your
desired pressure is reached.
NOTE: If the Preset Agitation is zero, start with
a value of 90. If the Preset Agitation pressure
is greater than 120 psi, start with a value of 60.
14. Turn the Booms, Agitation and Pump Switch
Off.
15. Refer to Initial System Field Test.
INITIAL SYSTEM FIELD TEST:
1. Drive Vehicle at desired spraying speed with
Sprayer Booms "OFF". Verify MPH readout on
Console by depressing SPEED.
2. Turn The Spray Pump Control switch to "ON".
3. Turn POWER, FOOT SWITCH ON/OFF, and
BOOM switches to "ON".
4. Place the MAN/RATE switch to RATE 1.
5. Increase or decrease vehicle speed by one
MPH (2 Km/h). The system should automatically
correct the target application rate.
If the system does not appear to be correcting
properly, first review the "INITIAL SYSTEM SET-
UP", then refer to the SERVICE MANUAL and
TROUBLESHOOTING GUIDE".
7. Verify area covered and volume used.
BEFORE SPRAYING
FILL FRESH WATER WASH TANK (See
FIG. 1):
1. Fresh Water Tank 2. Spigot
1. Turn Tank Spigot to ON position.
2. Hold contaminated area directly in water stream.
Flush thoroughly.
FIG. 1
1
1877
2
NOTE: Fill Fresh Water Wash Tank with clean
water only. Check to assure tank is full before
each operation.
In case of chemical contact with skin or eyes,
a fresh water wash tank has been installed on
the left side of the vehicle. Refer to the
Chemical Manufacturer's label for instructions
on seeking medical attention.
6. At the end of each swath sprayed, switch the
FOOT SWITCH ON/OFF to 'OFF' to shut off flow.
This also shuts off the acreage totalizer.