Service Bulletin

Customer Service Bulletin
Commercial Business Group
Multi Pro
®
1200 and 1250 Date: August 11, 2004
Model/Serial Range: Model Number: Serial Numbers:
41163 240000101-240000602
41164 240000101-240000450
41165 240000101-240000425
Subject: A capped vent may cause leaking.
The transaxle used on the Multi Pro 1200 and 1250 sprayers is vented to atmosphere
through a tube found at the right rear of the transaxle. During assembly this vent is
capped for purposes of cleanliness. The cap installed during assembly may have been
left in place which would plug the vent during operation. Leaks may result due to
excessive pressures caused by a plugged vent.
During service or maintenance of the affected units check for and remove caps or any
other obstruction that may impede venting.
Remove any caps or other obstructions
Ref: 09-13.doc Copyright, 2004. The Toro Company