Reference Guide

FormNo.3351-389RevC
NozzleSelectionGuide
forMulti-ProSprayersandWorkmanVehicles
ModelNo.AllModels
SelectionGuide
UsingtheNozzleSelection
Tables
Note:TheUnitDenitionsandConversionstableis
locatedon
Note:Tororecommendsavehiclespeedof3to5
MPH(5to9km/h)andanozzlepressureof30-50psi
(2.0-3.5Bar)whilespraying.
Thenozzleselectiontablesshowapplicationratesusing
specicnozzleswhilethevehicletravelsatavarious
speeds.
ThetablesshownozzleapplicationratesinUSGallons
perAcre,USGallonsper1,000ft
2
andLitersper
Hectare.Eachtableisorganizedbynozzleandeach
nozzlehasarangeofpressuresandvehiclespeedslisted.
Seethenozzleselectiontablesinthefollowingsection
toensurethatyourspraynozzleshavethecapacity
necessarytoachievethedesiredapplicationrate.
Thetablecanbeusedtoselectthecorrectnozzle.
Findthedesiredapplicationratewithinthe
appropriatetableatthepreferredvehiclespeedand
pressure,thenselectthenozzlethatislistedinthe
leftcolumns.
Example:
Thedesiredapplicationrateis24GPAforthe
materialtobesprayed.Thepreferredvehiclespeed
is5MPH.Thedesiredpressurerangeis30-50psi.
Findthedesiredspeedcolumnatthetopofthe
table.Followthatcolumndownuntilyouseeyour
desiredratewithinthe30-50psipressurerange.
Aslistedinthetable,thenozzlewithToropart
number95-9222hasanapplicationrateof23.8
GPAwhenthevehiclespeedis5MPHandpressure
wouldbe40psi.
Thetablecanbeusedtoverifythataspraynozzle
hasthecapacitynecessarytoachievetheapplication
rateselected.
Findthenozzleintheleftcolumnsoftheappropriate
table,thenlookforapplicationratewithinthat
sectionbyvaryingvehiclespeedand/orpressure.
Example:
TheyellownozzlewithToropartnumber95-9221
istheonlynozzleavailableandthematerialtobe
sprayedhasanapplicationrateof20GPA.
Ifvehiclespeedisslowedto3.5MPHandpressure
israisedto60psionecanachieveanapplicationrate
of20.4GPAwiththeyellownozzle.
SelectingaNozzle
GPAorUSGallonsper1000ft
2
1.Determinethedesiredapplicationratefromthe
manufacturer’slabeling.
Gallonsperacreorper1000ft
2
2.Determinethevehiclespeedtoapplythematerial.
MPH
3.Verifythatthenozzlespacingis20inches.
4.DeterminetheGallonsperMinuteusingeitherthe
appropriateNozzleSelectionTableorGPMformula
locatedattheendofthisguide.
GPM
5.SelectnozzlesizebasedonGPM.
6.Oncethenozzleisinstalled,spraywaterforinitial
test/calibration.PleaserefertotheCalibratingthe
SprayPro™MonitorsectionintheOperator’s
Manual.UsetheApplicationRateSwitchtoincrease
ordecreasetheapplicationrate.
©2010—TheToro®Company
8111LyndaleAvenueSouth
Bloomington,MN55420
Registeratwww.toro.com.
OriginalInstructions(EN)
PrintedintheUSA.
AllRightsReserved

Summary of content (20 pages)