Installation Instructions

Figure22
1.Switch,withnotchinthe
rear
3.Switchbody,rotated180°
2.Removethecover4.Installcover,notchinthe
front
C.Holdingtheswitchcoverinposition,ipthe
switchbody180degreessothattheconnector
notchisfrontleftcorner(
Figure22).
D.Presstherockerswitchcoversontotheswitch
bodiesinthisneworientationuntilthecover
snapsintoplace(Figure22).
E.Installtheswitchestotheiroriginalpositionin
thecontrolpanel.
Note:Ensurethattheorientationofthenotch
oftheswitchpointstowardthetopleftofthe
controlbox.
WiringtheSwitchesandIndicatorLight
1.Cutandremovetheexistinggrommetinthebaseof
thecontrolpanel.Discardthegrommet.
Important:Takeprecautionsnottocutthe
existingwiresandharnesswhencuttingoutthe
existinggrommet.
2.Routethefreeendofthewiringharnessupthrough
theopeninginthecontrolpanel,keepingthebranch
withtheringterminaloutsidethecontrolpanel.
3.Splitthenewgrommetincludedinthekitandwrap
thearoundthewiringharnessatthebaseofthe
controlpanel.
4.Installthegrommetstothebaseofcontrolpanelin
placeofthegrommetthatyouremovedpreviously.
5.Connecttheconnectorslabeled“leftboomlift
switch”and“rightboomliftswitch”tothe
correspondingpanelswitches.
6.Connecttheconnectorlabeled“sonicboomswitch”
tothesonicboomswitch.
7.Connectthelightindicatortothewiringharness
withtwospadeconnectors.
8.Installthefrontcontrolpanelcovertothecontrol
boxusingthefastenersthatyouremovedpreviously
(
Figure20).
9.Routetheremainderoftheharnessrearward,along
theexistingsprayerharnesstorearofthemachine.
10.Securetheharnesseswithcableties.
ConnectingtheWiringtotheFuseBlock
1.Locatethebranchofthewiringharness,withthe
ringterminalforgroundandsmallpowerterminal,
androuteitunderthedashtothefuseblockarea.
2.Connecttheringontheblackwiretotheground
bolt(
Figure23).
Figure23
1.Fuseblock4.Blackwire
2.Redwire,fromharness5.Groundbolt
3.Correspondingwire,from
fuseblock
3.Removetheshortextensionwirefromtheredwire
andconnecttheblackconnectortothemating
connectorinthefuseblock.
4.Locatethelongbranchextendingfrommiddleof
thewiringharnesswiththepositiveringterminal.
5.Routethelongbranchalongexistingwiringtothe
batteryarea.
6.Removethebatterycoverifnecessaryandconnect
theringterminaltothepositivebatterypostclamp
usingexistingfasteners.
12