Operator's Manual

ElectricalSystem
Maintenance
Fuses
TheWorkman
®
200SpraySystemaddsafuseblock
tothevehiclesexistingelectricalsystem.Itislocated
beneathdashboardwiththeexistingfuseblock(s).
Figure52
1.Foammarker(optional),
15A
3.ThermalBreaker,right
boom,30A
2.ThermalBreaker,left
boom,30A
4.Spraysystem,10A
Thetwothermalbreakersaccommodatetheleftand
rightactuatorsindependently.Theycandisruptpower
totheactuatorswhenoverheatedtoavoiddamagingthe
internalmotoroftheactuators.
Note:Oncethethermalbreakerhasbeentrippedthe
systemmustbeallowedtocooldownbeforeoperation
toresume.
SpraySystem
Maintenance
InspectingtheHoses
ServiceInterval:Every200hours
Every400hours/Yearly(whichever
comesrst)
Examineeachhoseinthespraysystemforcracks,
leaksorotherdamage.Atthesametime,inspectthe
connectionsandttingsforsimilardamage.Replaceany
hosesandttingsifdamaged.
PumpMaintenance
InspectingthePump
ServiceInterval:Every400hours/Yearly(whichever
comesrst)—Inspectthepump
diaphragmandreplaceifnecessary.
(seeanAuthorizedToroService
Distributor)
Every400hours/Yearly(whichever
comesrst)—Inspectthepressure
dampenerbladderandreplaceif
necessary.(seeanAuthorizedToro
ServiceDistributor)
Every400hours/Yearly(whichever
comesrst)—Inspectthepump
checkvalvesandreplaceifnecessary.
(seeanAuthorizedToroService
Distributor)
Note:Thefollowingmachinecomponentsare
consideredpartssubjecttoconsumptionthroughuse
unlessfounddefectiveandarenotcoveredbythe
Warrantyassociatedwiththismachine.
HaveanAuthorizedToroServiceDistributorcheck
followinginternalpumpcomponentsfordamage:
Pumpdiaphragm
Pressuredampenerbladder
Pumpcheckvalvesassemblies
Replaceanycomponentsifnecessary.
AdjustingtheAirPressureinDampener
Theairpressureinthedampeneronthepumpissetat
15psi(1bar)bythemanufacturer.Therecommended
pressureinthedampeneris1/3ofthesprayingpressure.
Ifusingaspraypressuregreaterthan45psi(3.1bar)
adjustthedampeneraccordingly.
44