Operator's Manual

Boom Lift Switches
T he electric boom lift switc hes raise and lo w er
their respecti v e booms ( Figure 30 ). T here is a left
and right lift switc h. Press and hold the switc h
upw ard to raise the respecti v e boom, or press and
hold the switc h do wnw ard to lo w er the respecti v e
boom.
Sonic Boom and Foam Marker Switch
Locations (Optional)
If y ou install the sonic boom and/or the foam
mark er kit, y ou will add switc hes to the control
panel for controlling their operation. T he spra yer
comes with plastic plugs in these locations .
Rate Control Valve
T his v alv e , located behind the tank ( Figure 31 ),
controls the amount of fluid that is routed to the
booms b y directing fluid flo w to the booms or the
b ypass hose to the agitation v alv e . Y ou can control
this v alv e in tw o w a ys: the application rate switc h
or man ually . T o control it man ually , y ou need to
disconnect the wire connector on the v alv e , then
y ou can rotate the knob on top of the v alv e to
man ually obtain the desired application rate .
Figure 31
1. Rate control valve 3. Boom valves
2. Flowmeter
Flowmeter
T he flo wmeter measures the flo w rate of the fluid
for use b y the Spra y Pro system ( Figure 31 ).
Boom Valves
T hese v alv es tur n the three booms on or off
( Figure 31 ). If y ou do not ha v e a boom installed
or do not w ant a boom to be able to be tur ned
on, y ou can man ually operate eac h v alv e b y
disconnecting the wire connector in the v alv e , then
rotate the knob on the v alv e cloc kwise to tur n the
v alv e off or countercloc kwise to tur n it on.
Boom Bypass Valves
T he boom b ypass v alv es redirect the fluid flo w for
a boom to the tank when y ou tur n off the boom
section. Y ou can adjust these v alv es to ensure that
the boom pressure remains constant no matter
ho w many booms are on. R efer to Calibrating the
Boom Bypass V alv es , in the Operation section.
Agitation Control Valve
T his v alv e is located on the right side of the tank
( Figure 32 ). T ur n the knob on the v alv e to the
9 o’cloc k position to tur n on the tank agitation
and to the 3 o’cloc k position to tur n off the tank
agitation.
Figure 32
1. Agitation control valve
2. Pressure gauge
Note: F or agitation to w ork, the PTO and clutc h
m ust be eng ag ed, and the engine m ust be r unning
abo v e an idle . If y ou stop the spra yer and need
agitation on, place the rang e shift lev er in the
Neutral position, let out the clutc h, set the parking
brak e , and set the hand throttle (if equipped).
Pressure Gauge
T he pressure g aug e is located to the right of the
tank ( Figure 32 ). T his g aug e sho ws the pressure of
the fluid in the system in psi and bar .
28