Operator's Manual

Spray Pro™ Monitor
T he Spra y Pro monitor displa ys and monitors
v arious system perfor mance data suc h as v ehicle
speed and application rates . It does not control
the application rate .
T he monitor has an LCD screen that displa ys the
data y ou select, a selection dial, and 4 buttons for
calibrating the monitor ( Figure 35 ).
Figure 35
1. LCD screen
6. Application rate 11. Reset, calibration button 16. Select units
2. Selection dial
7. Distance
12. Calibrate, calibration button 17. Width
3. Total area 8. Sub Area 13. Decrease, calibration button 18. Speed calibration
4. Speed 9. Sub volume 14. Increase, calibration button 19. Flowmeter calibration
5. Units of measure 10. Total volume 15. Boom selection
20. LED
Monitor Display Selection Dial
Use the dial to set the LCD screen displa y to the
follo wing:
T otal ar ea
Displa ys the total acres (US), hectares (SI), or
sq feet (TURF) that y ou ha v e co v ered since
y ou last pressed the R eset calibration button
for this setting .
Speed
Displa ys the g round speed in miles per hour (if
the Units of Measure is set to US or TURF) or
kilometers per hour (if the Units of Measure
is set to SI).
Units of Measur e
Displa ys the cur rent measurement unit
selection as follo ws:
US (United States measuring system)
SI (metric system)
TURF (as US but the v olumes are in US
g allons per 1000 sq ft instead of US g allons
per acre)
Application R ate
Displa ys the application rate in US g allons per
acre (US), liters pre hectare (SI), or US g allons
per 1000 sq ft (TURF).
Sub Ar ea
Displa ys the total acres (US), hectares (SI), or
sq feet (TURF) that y ou ha v e co v ered since
y ou last pressed the R eset calibration button
for this setting, without affecting the T otal
Area displa y . If y ou press the R eset calibration
button, the Sub V olume resets .
Distance
30