Operator's Manual

Calibrating the Spray Pro
Monitor
Figure 39
1. LCD screen
6. Application rate 11. Reset, calibration button 16. Select units
2. Selection dial
7. Distance
12. Calibrate, calibration button 17. Width
3. Total area 8. Sub Area 13. Decrease, calibration button 18. Speed calibration
4. Speed 9. Sub volume 14. Increase, calibration button 19. Flowmeter calibration
5. Units of measure 10. Total volume 15. Boom selection
20. LED
T he Spra y Pro monitor has a calibration mode that
allo ws y ou to c hang e v arious settings to customize
the displa y and calibrate the monitor to y our needs .
Y ou can calibrate or c hang e the follo wing settings:
Boom Width
Units of Measure
Speed
Flo wmeter
Setting the Boom Width
T he default settings for the boom widths are 80
inc hes (200 cm) for the right and left booms and
60 (150 cm) for the center boom. T his is based on
4 nozzles on the right and left booms and 3 on
the center boom all spaced 20 inc hes (50.8 cm)
apar t. If y ou c hang e the spacing of the nozzles ,
y ou should c hang e the boom width to reflect y our
c hang es as follo ws:
1. Stop the spra yer and set the parking brak e .
2. Set the master boom switc h to the Off
position. T he monitor displa ys “HOLD”.
3. Press and hold the Calibrate button until the
monitor displa ys “CAL HOLD” and the red
light on the monitor illuminates .
4. T ur n the selection dial to the T otal Area
position.
5. Use the Increase or Decrease calibration
buttons to select the boom for whic h y ou wish
to c hang e the width, where 1 is the left boom,
2 is the center boom, and 3 is the right boom.
6. T ur n the selection dial to the Sub Area
position.
7. Use the Increase or Decrease calibration
buttons to c hang e the boom width as needed.
8. R e peat ste ps 4 through 7 for the other booms
as needed.
9. Press the Calibrate button until the red light
tur ns off . Y ou can also exit the calibration
mode b y dri ving the spra yer .
36