Operator's Manual

Problem
Possible Cause Corrective Action
1. The monitor cable is
loose.
1. Connect the monitor
cable.
2. The ow meter is dirty or
clogged.
2. Clean the ow meter.
3. The ow meter is not
calibrated correctly.
3. Calibrate the ow meter.
The monitor does not
display Application Rate or
Total Volume.
4. The ow meter is
damaged.
4. Contact your Authorized
Service Dealer.
1. The ow meter is dirty or
clogged.
1. Clean the ow meter.
2. The ow meter is not
calibrated correctly.
2. Calibrate the ow meter.
The Total Volume is
inaccurate.
3. The ow meter is
damaged.
3. Contact your Authorized
Service Dealer.
The monitor displays 6553.5
when in the Application Rate
setting.
1. The monitor is not
receiving data from the
speed sensor.
1. Contact your Authorized
Service Dealer.
The monitor is erratic in
operation.
1. A two-way radio is too
close to the monitor or
its cables.
1. Keep two-way radios
away from the monitor
and its cables.
The displayed
measurements do not
make sense.
1. The Units of
Measurement is set
to a system other than
what you expect.
1. Check the Units of
Measurement to ensure
that it is set correctly.
The monitor reads “OFL.”
1. The data has exceeded
the maximum allowed.
1. Press and hold the
[Reset] button to clear
the monitor.
51