3.Useliquidsoaptocoatthehosebarbofthetee
connectionsonbothextensionbooms(Figure32).
Installtheboomextensionhoseoverthebarband
secureitwithaclamp.
G012929
1
2
3
5
8
6
4
7
9
Figure32
1.Boomextension6.Boomhose
2.Boomhose
7.Clamp
3.Clamp8.Grommet
4.Teeconnection9.Teeconnection
5.Centerboom
4.Useliquidsoaptocoatthehosebarbofthecenter
boomteeconnectionFigure32.
5.Routethecenterboomhosethroughthegrommeted
openinginthecenterboomassembly.Connectthe
centerboomsupplyhosetothesoapedbarbandsecure
itwithahoseclampFigure32.
13
InstallingtheNozzles
NoPartsRequired
Procedure
Thenozzlesyouusetoapplyyourchemicalsvarydepending
ontherateofapplicationthatyouneed;therefore,nozzles
arenotsuppliedwiththekit.Toobtainthecorrectnozzles
foryourneeds,contactyourAuthorizedToroDistributorand
bepreparedtogivethemthenfollowinginformation:
TherecommendedapplicationrateinUSgallonsper
acre,USgallonsper1000sqft,orlitersperhectare.
Thetargetspeedofthevehicleinmilesperhouror
kilometersperhour.
Thenozzlespacing(typically20inchesor50cm).
Toinstallanozzle,completethefollowing:
1.Threadorinsertthenozzleintothenozzlereceptacle
followedbyagasket.
2.Slidethenozzlereceptacleoverthenozzlettingon
aturret.
3.Turnthenozzleclockwisetolockthecamsonthe
receptacleinplace.
4.Verifythefanportionofthenozzle.
SeetheInstallationInstructionsaccompanyingthenozzlesfor
moreinformation.
14
CompletingtheSetup:
Learningmoreaboutyour
product.
Partsneededforthisprocedure:
1
Operator'sManual
1
OperatorTrainingMaterial
1
PartsCatalog
1
RegistrationCard
1
Selectionguide
1
Pre-deliveryInspectionSheet
Procedure
1.Readthemanuals.
2.ViewtheOperatortrainingmaterial.
3.Usethenozzleselectionguidetochoosethecorrect
nozzlesforyourspecicapplication.
4.Storethedocumentationinasafeplace.
24