Installation Instructions

Maintenance
RecommendedMaintenanceSchedule(s)
MaintenanceService
Interval
MaintenanceProcedure
Every200hours
Cleantheowmeter(Moreoftenwhenusingwettablepowders).
Yearly
Calibratetheowmeter.
CleaningtheFlowmeter
ServiceInterval:Every200hours
1.Thoroughlyrinseanddraintheentiresprayingsystem.
2.Removetheowmeterfromthesprayerandushit
withcleanwater.
3.Removetheretainerringontheupstreamside(Figure
11
).
G012934
8
7
9
1
4 5
2
3
6
5
Figure11
1.Modiedangedbody
6.Turbinestudassembly
2.Rotorormagnetassembly
7.Cableclamp
3.Huborbearingassembly8.Threadscrew
4.Hubassembly(with
keywayup)
9.Sensorassembly
5.Retainerring
4.Cleantheturbineandtheturbinehubtoremovemetal
lingsandanywettablepowders.
5.Inspecttheturbinebladesforwear.
Note:Holdtheturbineinyourhandandspinit.It
shouldspinfreelywithverylittledrag.Ifitdoesnot
spinfreely,replaceit.
6.Assembletheowmeter.
7.Installthesensoruntilitgentlytouchesthebottom
ofthehousing.
8.Carefullytightenthesensorretainingnuts.
9.Usealowpressure(50kPaor5psi)airjettoensure
thattheturbinespinsfreely.Ifitdoesnotspinfreely,
loosenthehexstudonthebottomoftheturbinehub
by1/16ofaturnuntiltheturbinespinsfreely.
ProgrammingtheConsole
Computer
Withthecontrollerpoweroff,pressandholdtheCEbutton
andmovethepowerswitchontheconsolecomputertothe
Onposition.
Note:TurningthepowerswitchtotheOffpositionor
disconnectingtheconsolecablesdoesnoterasethedata
storedintheconsolecomputermemory.
Important:Thecalibrationguresgivenareguidelines
only;youshouldperformcalculationsforyourparticular
machineandsprayingapplicationsituationand
conditions.
Note:Referto
Figure9andtheKeypadReferenceTable
(page8)forthedescriptionandfunctionofthekeysonthe
consolecomputer.
Toprogramthecomputerconsole,refertoInitially
ProgrammingtheConsoleComputerintheOperation
section.
Note:Allthedataisretainedwhenyouturnthepower
switchtotheOffposition.
CalculatingtheBoomCalData
ThesettingsintheProControlXPareautomaticallysetto
thedefaultsettings.However,youcanchangethevaluesif
thenozzlespacinghaschanged.
CalculatetheBoomCalbymultiplyingthenumberofspray
tipsbythetipspacing.
Note:Boom1istheleftboom(fromtheoperatingposition),
Boom2isthecenterboom,andBoom3istherightboom.
1.Pressthe[Boom1Cal]key.
2.Pressthe[Enter]key.
3.Enter80(USorTU)or204(SI).
13