Installation Instructions

4.Pressthe[Enter]key.
5.Pressthe[Boom2Cal]key.
6.Pressthe[Enter]key.
7.Enter60(USorTU)or152(SI).
8.Pressthe[Enter]key.
9.Pressthe[Boom3Cal]key.
10.Pressthe[Enter]key.
11.Enter80(USorTU)or204(SI).
12.Pressthe[Enter]key.
EnteringtheSpeedCalNumber
TheSpeedCalnumberiscriticaltotheperformanceofthe
spraysystem.Ensurethatthetiresareproperlyinatedand
thatthetankishalffullbeforeperformingthisprocedure.
1.Pressthe[SpeedCal]key.
2.Pressthe[Enter]key.
3.EnterthecorrectSpeedCalnumberforyourcurrent
selectedunitofmeasurement(US,SI,TU).
WhenusingUSunits,enter:148.
WhenusingSIunits,enter:38.
WhenusingTUunits,enter:148.
4.Pressthe[Enter]key.
Note:Thesenumberallowthemachinetooperate
withreasonableaccuracy.Finetuningisnecessaryfor
maximumaccuracy.
Fine-tuningtheSpeedCalNumber
Thefollowingprocedurerequiresbuttons1through8to
havebeenpopulatedwithdataandtheCALtostopashing.
Usethefollowingproceduretofurtherne-tunetheSpeed
Calnumber:
1.Measure152m(500feet)onaatgroundsurface.
2.Setthedistancereadoutto0.
3.Pressthe[Distance]key.
4.Pressthe[Enter]key.
5.Enter0.
6.Pressthe[Enter]key.
7.Drivethevehicle152m(500feet).
8.Ensurethatthedistancereadoutontheconsole
computerreadsbetween149mand155m(490feet
and510feet).
9.Ifthereadoutisnotbetween149mand155m(490
feetand510feet),calibratetheSpeedCalusingthe
followingequation:
NewSpeedCalnumber=148x500/Distance
readout(forUSorTUunits)
NewSpeedCalnumber=38x152/Distance
readout(forSIunits)
10.EnterthenewSpeedCalnumberusingtheEntering
theSpeedCalNumberprocedure.
EnteringtheValveCalNumber
TheValveCalnumbercontrolstheresponseofthespray
systemtomeetthechangesofthevehiclespeed.
Important:Runningthecontrolvalvetoofast(anumber
greaterthanzero)willcausethesystemtooscillate.
ToentertheValveCalnumber:
1.Pressthe[ValveCal]key.
2.Pressthe[Enter]key.
3.EntertheValveCalcalibrationnumber.
Note:TheinitialvalvecalibrationnumberforValve
Calis023.Werecommendthatyouusethisnumberfor
mostsprayapplications;046maybehelpfulforsmall
applicationrates(1.5liters/min.or0.4gallons/min.).
4.Pressthe[Enter]key.
EnteringOptionalCalibrationValues
Youmayalsowanttoenterthefollowingdata,butitisnot
requiredforoperatingthespraysystem.
VolumeTank
Thisnumberrepresentsthevolumeofmaterialinthetank
andmustbeenteredeachtimeyourellthetank.The
functionmonitorsthetankvolumewhileyouarespraying
basedonthetotalamountapplied.
1.Pressthe[Vol/Tank]key.
2.Pressthe[Enter]key.
3.Entertheamountofmaterialinthetank.
4.Pressthe[Enter]key.
Time
Enterthetimeofdaybasedona24-hourday.Forexample,
1:30p.m.is13:30.Youcanalsoenter0tomeasureelapsed
time.
Tosetthedate,dothefollowing:
1.Pressthe[Time]key.ThedisplayshowsMONTH.
2.Pressthe[Enter]keytochangethemonth.
3.Pressthe[Time]key.ThedisplayshowsDAY .
4.Pressthe[Enter]keytochangetheday.
5.Pressthe[Time]key.
ThedisplayshowsYEAR.
6.Pressthe[Enter]keytochangetheyear.
7.Pressthe[Time]key.
ThedisplayshowsPOWERDOWNDAY .
14