Installation Instructions

Operation
Theconsolecomputerautomaticallycontrolsthespray
applicationrateforvaryingvehiclespeeds.Yousetthetarget
volumeperunitareatosprayandtheconsolecomputer
automaticallymaintainstheowwithintheproperrangeof
thevehiclespeedandcontinuallydisplaystheactualvolume
ofmaterialperareasprayed.Theconsolecomputeralso
monitorstheareasprayed,thespeedofthevehicle,andthe
totalvolumeofmaterialsprayed.
Important:Amanualoverrideswitchallowsthe
operatortomanuallycontroltheowforsystem
inspectionandspotspraying.
Note:Iftheconsolecomputermalfunctions,youcanspray
manuallybyunpluggingthecablesfromtherearofthe
consolecomputer.Youcanthencontrolthesprayapplication
rateusingthecenterconsolecontrols.
Inthissection,theprocedurewillusethefollowingnaming
convention:
Thelabelsontheconsolecomputerkeysareenclosedin
brackets.Forexample:Pressthe[Enter]key.
Thedatayouenterisinboldfacetypeprecededbythe
wordPress.Forexample:Press123.
Thedatashowninthedisplayisinnormaltype,with
lettersinallcaps.
InitiallyProgrammingthe
ConsoleComputer
Youmustrstprogramtheconsolecomputerbeforeyou
canuseittooperatethespraysystem.Youneedtoperform
thisoperationonlywhenyouturnontheconsolecomputer
forthersttime.
TurnthepowerswitchtotheOnposition.
Note:TheconsolescreenshowsthemessageCALinthe
display.
SelectingUS,SI,orTU
ToselecttheunitsforUS(volumeperacre),SI(volumeper
hectare),orTU(volumeper1,000sq.ft.):
1.Pressthe[CE]keyuntilyouseeyourdesiredcode(US,
SI,TU)inthedisplay.
2.Pressthe[Enter]key.
Note:Ifyoumakeadataentryerror,resettheconsole
computerbyturningthepowerswitchtotheOff
positionand,whilepressingandholdingthe[CE]key,
turningthepowerswitchtotheOnposition.
EnteringtheMeterCalNumber
UsethegalloncalibrationnumberforUSgallonsperacre
orUSgallonsper1000sq.ft.oralitercalibrationnumber
forlitersperhectare.
1.Pressthe[MeterCal]key.
2.Pressthe[Enter]key.
3.EntertheMeterCalcalibrationnumber.
Note:TheMeterCal(orowmeter)calibration
numberisstampedonthetagattachedtotheowmeter
ormetercable(
Figure10).
G017270
METER
CAL
1750 Ga l.
[463 (LITER)]
1
2
Figure10
1.Tag2.Flowmeter
4.Pressthe[Enter]key.
EnteringRate1andRate2Data
Enterthesprayapplicationrate(withdecimal)inRate1and
Rate2.EntertheratesinUSgallonsperacre(USmode),US
gallonsper1,000squarefeet(TUmode),orlitersperhectare
(SImode)dependingonthebasemeasurementyouselect.
1.Pressthe[Rate1Cal]key.
2.Pressthe[Enter]key.
3.Enterthetargetapplicationrate(ingal.peracre,liters
perhectare,orUSgallonsper1,000sq.feet)thatyou
wanttospray.
4.Pressthe[Enter]key.
5.Pressthe[Rate2Cal]key.
6.Pressthe[Enter]key.
7.Enterasecondtargetapplicationrate(inUSgallons
peracre,litersperhectare,orUSgallonsper1,000sq.
ft.)thatyouwanttospray,ifyoudesire.
Note:Rate2shouldnotdiffermorethan20%from
Rate1unlessthereisachangeinnozzlesize.Ifyoudo
notuseasecondrate,enterthesamerateforRate1
andRate2.
9