Installation Instructions

Figure27
2015Machines
1.Fuseblock
7.Locknut(#10–24)
2.Fuse(40A)
8.5-socketconnector
(machinewireharness)
3.Boltandnut(electrical
panel)
9.Relay
4.2-pinconnector(delay
timer)
10.4-socketconnector
(machinewireharness)
5.2-socketconnector
(machinewireharness)
11.Powerrelay
6.Flange-headbolt(#10-24
x1/2inch)
Figure28
2016andAfterMachines
1.Fuse(40A)5.Flange-headbolt(#10-24
x1/2inch)
2.Fuseblock6.4-socketconnector
(machinewireharness)
3.Locknut(#10-24)
7.Relay
4.Electricalpanel
3.Installafuse(40A)totheopenslotinthefuseblock
asshowninFigure26,Figure27,orFigure28.
Note:Ifaloweramperagefusealreadyexistsinthe
slot,replaceitwiththefuse(40A).
4.Locaterelayandpowerrelayinlinewiththeotherrelays
ofthesamestyle,andmountthemtothepanel(Figure
26,Figure27,orFigure28)withthe2ange-head
bolts(#10-24x1/2inch)and2locknut(#10-24).
5.Locatethe4-socketconnectorandthe5-socket
connectoronthemainharnessandconnectthemto
therelay(4-pin)andpowerrelay(5-pin)asshownin
Figure26,Figure27,orFigure28.
12