Form No. 3412-156 Rev C X30 GeoLink® Precision Spray System Kit Model No. 41623—Serial No. 317000001 and Up Model No. 41624—Serial No. 317000001 and Up Model No. 41625—Serial No. 317000001 and Up Note: Contact Toro® NSN® at 1-844-GEO-LINK or NSNTech@toro.com for customer service. Register at www.Toro.com.
WARNING CALIFORNIA Proposition 65 Warning This product contains a chemical or chemicals known to the State of California to cause cancer, birth defects, or reproductive harm. Use of this product may cause exposure to chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. g000502 Figure 1 1. Safety-alert symbol This manual uses 2 words to highlight information.
Safety Read and understand the contents of this Operator’s Manual before operating the console computer. • Keep these instructions with the Operator’s Manual for the turf sprayer. • It is very important that all who operate this equipment have ready access to these instructions at all times. • Read these instructions and the instructions in the Operator’s Manual for the turf sprayer carefully. Be familiar with the controls and the proper use of the equipment.
Product Overview g204997 Figure 2 Control console g204996 Figure 3 Satellite receiver g204995 Figure 4 Automatic section and application rate controller (ASC) g205645 Figure 5 Turbine-type flowmeter g205646 Figure 6 Pressure transducer 4
Controls – Auto (uses the light sensor in the control console to adjust the screen brightness) Screen Brightness Buttons – Day mode (preset screen brightness for machine operation during bright ambient light) Use the SCREEN BRIGHTNESS icons (Figure 7) to adjust the screen brightness of the control console: – Night mode (preset screen brightness for machine operation during low ambient light) • Press the (-) SCREEN BRIGHTNESS button to reduce display brightness.
Help Button Implement Color Indicators The help button displays the names of the icons on the current screen (Figure 7). Pushing the help button displays the descriptive text for that control (Figure 9). Press the help button again to clear the individual help icons. These indicators show the position and direction of the vehicle and its implement. The implement color indicates the status of the product application as follows (Figure 11): • Red—the section is off.
Specifications Operation The following are important acronyms for the user to understand: The computer in the automatic section controller (ASC) controls the spray application rate for varying vehicle speeds. You set the target volume per unit area to spray, and the ASC automatically maintains the flow within the proper range of the vehicle speed and continually displays the actual volume of material per area sprayed.
Understanding the LED Lights g204034 Figure 12 Settings screen 1. Current access level g030700 Figure 13 2. List of access levels 1. LED light bar 3. Console battery-status LED 4. Supply-status LED 2. Light sensor Starting the Display 1. Ensure that the GeoLink components and finish kit are installed. • LED light bar—as the console powers up, the 2. Start the machine and wait a few seconds for the console to start.
Using the Touch Screen You access, add, or modify sprayer information on the display by touching the screen and working with the individual icons. • Select any icon on the screen to display what is shown on the screen. • Further options display when you press a particular icon. • Select options as required. • Confirm the new display (Figure 10). g203217 Selecting a Language and Accepting the License Agreement Figure 15 1. Selected language 3.
When the master switch icon is red, press the icon to display the master switch status, which shows the number of active alarms (Figure 17). g205202 Figure 17 g031187 Figure 19 At any time, press the confirm icon (Figure 17) to return to the main screen and complete the necessary corrective action. Selecting the Correct Units of Measure The following options are available: Metric, Imperial (US), and Imperial (UK).
Using the Easy Mode The easy mode is for spraying areas with defined boundaries, allowing you to select the jobs and display the spraying area. g206363 Figure 21 Easy-mode screen 1. System-information icon 6. Inventory-manager icon 11. Field-menu icon 16. Boundary-selection icon 2. Guidance icon 7. Setup icon 12. Quick-start icon 17. Boom-display icon 3. Job-information icon 8. Sprayer dashboard 13. Zoom-function icon 4. Auto-section control-configuration icon 9. Master-switch icon 14.
Boundary Limit Icon (cont'd.) Setting Description The operator of the turf sprayer manually turns the left, center, and right spray section on or off. Field Boundary disabled GeoLink provides no control of nozzle sections. GeoLink provides no control of pass-to-pass spraying overlaps. Rate Control Icon Setting Description Automatic (Auto) GeoLink controls the application rate based on the rate that you set for the active spray job or the rate you set in the sprayer control panel.
g209114 Figure 24 g209115 Figure 23 1. Auto-section control-configuration icon (ASC) 4. Boundary-limit icon 2. Sprayer-controller icon 5. Rate-control icon 1. Auto-section control-configuration icon (ASC) 3. ASC on/off icon 2. Sprayer-controller icon 4. Rate-control icon Spraying Manually 3. ASC on/off icon This spraying method allows the following: • The operator controls the boom sections. Spraying with Rate Control Only • The operator controls the application rate.
Creating a New Product Entry 1. Fill the tank with water. 2. Press the sprayer-controller icon and expand the sprayer-controller panel (Figure 26). g209113 Figure 25 1. Auto-section control-configuration icon (ASC) 3. ASC on/off icon 2. Sprayer-controller icon 4. Rate-control icon Creating a New Product Entry and Setting the Tank Volume Note: Ensure that the units are correct for your use. Refer to Selecting the Correct Units of Measure in the Operator’s Manual. g031295 Figure 26 1.
g206711 Figure 27 1. New product... icon 5. 2. Product selection list icon Press the NEW PRODUCT... icon, and press the confirm icon (Figure 27). g204241 Figure 29 The New Product Setup wizard displays. 6. On step 1 of the new product setup dialog box, press the icon, and press the next icon (Figure 28). 1. Display keyboard 4. Move cursor right icon 2. Backspace icon 5. Confirm icon 3. Move cursor left icon 8.
g204317 Figure 32 1. Product-application rate field (example: 0.012 gal/kft2) 3. Confirm icon 2. Numeric pad g204244 Figure 31 1. New product setup dialog box 2. New product rate increment icon 3. Back icon (previous step) A. 4. Progress bar B. Press the confirm icon (Figure 32). • Press the 1 or set the preset product application rates as follows: (Figure 31). PRODUCT RATE PRESET PRODUCT RATE PRESET 1 icons to 5. Product rate preset icons 6. Next icon (next step) A.
g205038 Figure 33 1. Preset -application rate field 2. Numeric pad 3. Confirm icon g206757 B. 10. Figure 34 Press the confirm icon (Figure 32). 1. Product configuration window 2. New product setup dialog box On step 4 of the new product setup dialog box, confirm icon (Figure 34). 11. 3. Confirm icon In the product configuration window, press the confirm icon to save the new product information (Figure 34). Entering Product Tank Volume 1. Press the TANK FILL icon (Figure 38).
2. Press the VOLUME icon (Figure 35). 3. Use the numeric pad of the display to enter 1 of the following: Note: Press the or icons to enter a preset increment of product volume quantity. INCREMENT VALUE DECREMENT VALUE g204242 Figure 37 g204276 1. Old product tank volume Figure 36 1. Decrement value icon 4. Numeric pad 2. Increment value icon 3. Product volume field (example: 100.00 gal) 5. Confirm icon 2.
g204243 Figure 39 Incrementally adding product g204245 Figure 38 1. Volume increment icon 2. Decrease increment icon 5. 3. Increase increment icon 4. New volume increment value Use the numeric pad of the display to enter increment of the volume of product (such as chemicals to water) that you will add product to the tank, and press the confirm icon (Figure 39). Example: 19 L (5 gallon), 114 L (30 gallon), or 208 L (55 gallon) increments. 6. 1. Volume of water in the tank (example: 100.00 gal) 5.
Using the Easy Mode with a New Job Setting the Application Rate and Naming the Job 1. Start the machine and keep the key in the RUN position. 2. Open the sprayer-controller icon (Figure 40). g205052 Figure 42 1. Current rate field 2. Numeric pad g031532 Figure 40 3. Confirm icon 1. Sprayer-controller icon 5. 3. In the sprayer-controller screen, determine if the correct preset application set. 4.
Selecting the Spray Nozzle 1. B. In the new job menu, press the nozzle icon (Figure 44). Select the excluded regions that are not to be sprayed (bunkers, trees, hazards, etc.) (Figure 45). Note: Refer to the standard mode videos for spraying a boundary inside another boundary. Operating the Sprayer System of the Machine 1. Set the 3 section switches (located in the control console of the machine) to the ON position (Figure 46). g205214 Figure 44 1. Nozzle icon 2. 2.
Using the Easy Mode with an Existing Job Note: A job is set up in the standard mode. Ensure that any previous job information is deleted before repeating an existing job. 1. Start the machine and keep the key in the RUN position. 2. Open the sprayer-controller icon (Figure 47). g203549 Figure 49 1. List of existing fields 3. Field-menu icon 2. Field-list icon g031532 Figure 47 1. Sprayer-controller icon 3. In the sprayer-controller screen, determine if the correct rate (gal/ac) is selected. 4.
g205685 Figure 51 1. Left-section switch 3. Right-section switch 2. Center-section switch 10. To start spraying, press the MASTER SWITCH icon on the screen and drive into the spray area (Figure 21). Note: The machine starts spraying when the sprayer crosses into the correct spray area. Note: The display shows areas to be sprayed as light gray and non-spray areas as dark gray. If the display shows all light gray, every area can be sprayed.
Using the Standard Mode g206364 Figure 52 1. System-information icon 6. Inventory-manager icon 11. Job-menu icon 16. Center-map view 2. Guidance icon 7. Setup icon 12. Field-menu icon 17. Boundary-selection icon 3. Job-information icon 8. Sprayer dashboard 13. Quick-start icon 18. Section-display icon 4. Auto-section control icon 5. Sprayer-controller icon 9. Master-switch icon 10. Receiver calibration icon 14. Zoom-function icon 15.
Calibrating the Compass 1. Select the receiver calibration icon (Figure 53). 2. Select the compass icon (Figure 53). g209126 Figure 54 6. Confirm the calibration (Figure 53). Creating a Field Note: Create 1 field per course with all field boundaries for that course under that field. 1. Press the field-menu icon (Figure 55). 2. Press the new-field icon. 3. Select the field name, name the field, and press the confirm icon (Figure 55). g209223 Figure 53 1. Receiver calibration icon 3.
Creating a Nozzle 1. Set the user access level to STANDARD ; refer to Understanding the Different Display Modes (page 7). 2. Press the setup icon home screen. 3. Press the implement icon, boom icon, and nozzles icon (Figure 56). in the lower left of the g204393 Figure 57 1. Factory template selection (nozzle) 2. Next icon (next step) Nozzle Table Nozzle 04 05 06 08 10 15 g204392 Figure 56 1. Nozzle setup screen 2. New nozzle... icon 4. On the nozzle setup screen, press the NEW NOZZLE...
Calibrating the Flow Meter Customer provided equipment: A graduated catch container (a container with 0.01 ml (1/2 fl oz) increments is preferred). Preparing for the Calibration 1. Ensure that the sprayer tank is clean. 2. Fill the sprayer tank with at least 150 gallons of fresh water. 3. Ensure that the nozzles that you intend to test are in the active spray (down) position. 4. Engage the parking brake and start the engine. Note: Allow the engine and hydraulic system to warm for 10 minutes.
8. Perform the catch test for at least 15-seconds or more at 1 of the nozzles (Figure 62). Note: The length of the catch test depends on the size of the container, but more time is best. 9. 10. Shut off the master section switch, set the throttle to the slow position, and shut off the spray pump. Set the graduated container on a level surface and note the fluid volume (Figure 63). Important: When you are reading the graduated container, you must set the container on a level surface.
g211486 Figure 64 1. Run the catch test. 13. 2. Verify the fluid amount. Confirm the flow cal factor (Figure 65). g031535 Figure 66 1. Job-menu icon 3. List of information to change 2. Record-job information icon Recording Job Notes Use the notes area to record any information for each job. 1. Open the job-information icon (Figure 67). g211487 Figure 65 1. Key pad Recording Job Details The job menu selects or sets up specific job information associated with the chosen area.
Exporting Job Information Note: Ensure that a job is in session before exporting job information. 1. Remove the cap for the USB port located on the left side of the display (Figure 68). g031537 Figure 69 1. Job-menu icon 3. Export job report to USB icon 2. Data-exchange icon g206639 Figure 68 1. USB storage device 3. USB socket 2. Cap 2. Insert a USB storage device into the USB socket (Figure 68). 3. Press the job-menu icon (Figure 69). 4. Press the data-exchange icon (Figure 69). 5.
g205127 Figure 72 Master section switch—Multi Pro 5800 turf sprayer, 2016 and after g206663 Figure 70 1. Eject USB icon 9. 2. Confirm icon (eject USB dialog box) Preparing the Machine At the eject USB dialog box, press the confirm icon and remove the USB storage device from the monitor (Figure 70). 1. Read through the following instructions before starting. 2. Attach the supply hose to the anti-siphon tube and fill the tank half full of clean water.
D. Press the switch window icon for the sprayer controller menu. The current home screen and the sprayer controller menu switches position. E. Press the configuration icon in the sprayer controller submenu to display to configuration menu (Figure 74). g203964 Figure 73 1. Auto section control configuration icon 3. ASC icon (OFF) 2. ASC icon (ON) B. C. g203967 Press the ASC icon to OFF (Figure 73). Press the sprayer-controller icon (Figure 74). Figure 75 1. Configuration icon F. 2.
2. Press the switch window icon to return sprayer controller menu. (Figure 74). 3. Enter the desired application rate by using the pre-sets, increase or decrease icons, or by selecting the current-target application rate icon (Figure 77). 5. Set the rate control to AUTO. Note: Ensure that either the ASC is OFF or the boundary limit set to UNLIMITED. 6. Select a target application rate. 7. Increase or decrease the vehicle speed by 2 km/h (1 mph).
Alarm List Improving the Application Rate Response Time The table that follows lists the alarms and the alarm descriptions: Set the agitation PWM (preset agitation value) to approximately 69 kPa (10 psi) above the target-spraying pressure. Alarm List Alarm Description ASC 10 ECU firmware mismatch Contact Toro NSN for customer service. Refer to the front cover for the correct contact information. Exclusion map distance The exclusion map is to far from the current GPS position.
Maintenance Recommended Maintenance Schedule(s) Maintenance Service Interval Maintenance Procedure • Clean the flowmeter (more often when using wettable powders). Every 200 hours Cleaning the Flowmeter 9. Service Interval: Every 200 hours 1. Thoroughly rinse and drain the entire spraying system. 2. Remove the flowmeter from the sprayer and flush it with clean water. 3. Remove the retainer ring on the upstream side (Figure 79).
Troubleshooting Note: If the console computer malfunctions or needs repair, you can control the system using the center-console controls. For many errors an error code, or trouble code, displays. It is also possible to view the errors on the screen. The errors listed below are common and are correctable. For other errors or if a problem persists, always record the error message to report to your distributor, including any code displayed.
Troubleshooting Topics Problem There is no power to the display. Possible Cause Corrective Action 1. The connectors are not installed correctly. 1. Ensure the connectors are installed correctly at the back of the display, 2. The fuse for the display is blown. 3. The battery connections are loose. 2. Replace the fuse. 3. Secure the battery connections. The monitor is frozen. 1. There is a malfunction with the software. 1.
Notes:
European Privacy Notice The Information Toro Collects Toro Warranty Company (Toro) respects your privacy. In order to process your warranty claim and contact you in the event of a product recall, we ask you to share certain personal information with us, either directly or through your local Toro company or dealer. The Toro warranty system is hosted on servers located within the United States where privacy law may not provide the same protection as applies in your country.
The Toro Warranty A Two-Year Limited Warranty Conditions and Products Covered The Toro Company and its affiliate, Toro Warranty Company, pursuant to an agreement between them, jointly warrant your Toro Commercial product (“Product”) to be free from defects in materials or workmanship for two years or 1500 operational hours*, whichever occurs first. This warranty is applicable to all products with the exception of Aerators (refer to separate warranty statements for these products).