Operator's Manual

g280778
Figure36
1.Hydrauliclter2.Filtermount(hydraulic
manifold)
3.Lubricatethegasketofthenewlterwiththe
speciedhydraulicuid;refertoHydraulicFluid
Specications(page27).
4.Cleanthelter-mountingareaofthehydraulic
manifold(Figure36).
5.Threadthelterontotheltermountuntilgasket
manifold,thentightenlterone-halfturn.
6.Towmachinetopowerthehydraulicsystemand
checkforhydraulicleaks.
ChangingtheHydraulic
Fluid
ServiceInterval:Every2,000hours—Ifyou
areusingtherecommended
hydraulicuid,changethe
hydraulicuid.
Every800hours—Ifyouarenotusingthe
recommendedhydraulicuidorhaveever
lledthereservoirwithanalternativeuid,
changethehydraulicuid.
Hydraulicreservoiruidcapacity:approximately
9.5L(2.5USgallon)
Important:Ifuidbecomescontaminated,
contactyourauthorizedTorodistributorbecause
youmustdrainthecompletehydraulicsystem.
Contaminateduidlooksmilkyorblackwhen
comparedtocleanoil.
1.PerformthestepsinPreparingforMaintenance
(page20).
2.Alignadrainpanwitha9.5L(2.5USgallon)
capacityunderthehydraulicmanifold(Figure
37).
g280774
g280775
Figure37
1.Hydraulicmanifold3.Fitting(hydraulicmanifold)
2.Returnhose
3.Removethereturnhosefromthettinginthe
hydraulicmanifoldandallowthehydraulicuid
todraincompletely(Figure37).
4.Installandtightenreturnhose(Figure37).
5.Cleanareaaroundllerneckandcapof
hydraulicreservoir,andremovethecap;referto
Figure35inCheckingtheHydraulicFluidLevel
(page28).
6.Addapproximately9.5L(2.5USgallon)ofthe
speciedhydraulicuid;refertoHydraulicFluid
Specications(page27).
Important:Useonlyhydraulicuids
specied.Otheruidscouldcausedamage
tocomponentsofthehydraulicsystem.
7.Checklevelofuidandaddenoughtotheuid
levelstatedinCheckingtheHydraulicFluid
Level(page28).
Important:Donotoverllthereservoirwith
hydraulicuid.
8.Installhydraulic-reservoircap;refertoFigure35
inCheckingtheHydraulicFluidLevel(page28).
29