Operator's Manual

8
Setup
Note: Use this chart as a checklist to ensure that all parts have been received. Without these parts, total setup cannot be
completed.
Description
Qty. Use
Hitch Assembly 1 Mount to debris blower
Operator’s Manual 1 Read before operating the machine.
Parts Catalog 1
Note: Determine the left and right sides of the machine
from the normal operating position.
Activating the Battery
Battery posts, terminals, and related accessories
contain lead and lead compounds, chemicals
known to the State of California to cause cancer
and reproductive harm. Wash hands after
handling.
Warning
The factory ships the debris blower with a dry battery.
Purchase bulk electrolyte with 1.260 specific gravity from a
local battery supply outlet.
1. Remove (6) bolts and washers securing battery cover to
chassis (Fig. 1).
1
Figure 1
1. Battery cover
2. Remove the wing nuts, rods and battery holddown
securing battery to blower chassis (Fig. 2).
1
Figure 2
1. Battery holddown
3. Lift the battery out of the chassis.
Danger
Battery electrolyte contains sulfuric acid which is a
deadly poison and causes severe burns.
Do not drink electrolyte and avoid contact with
skin, eyes or clothing. Wear safety glasses to
shield your eyes and rubber gloves to protect
your hands.
Fill the battery where clean water is always
available for flushing the skin.
4. Remove filler caps from the battery.