Service Manual

ProPass 200 Page 3 -- 23 Hydraulic System
Problem Possible Causes
Floor does not function (machines with standard
hydraulics).
Floor control valve setting is not adjusted properly.
Floor solenoid valve is faulty.
An electrical problem exists (see Chapter 4 -- Electrical
System).
Hydraulic floor motor is faulty.
Floor does not function (machines with electronic
hydraulics).
NOTE: Check wireless remote LCD display and base
unit LED’s for help in troubleshooting.
Wireless remote settings are incorrect.
Control manifold proportional solenoid valve (SP1) is
faulty.
An electrical problem exists (see Chapter 4 -- Electrical
System).
Hydraulic floor motor is faulty.
Hydraulic
System