Service Manual

ProPass 200Page 3 -- 36Hydraulic System
Check Valve Service
The ProPass control manifold includes four (4) check
valves used for circuit control. Check valve location is
identified in Figure 37. Remove check valves from mani-
fold for cleaning or replacement. Replace seal kit on
check valves if removed from manifold. Torque check
valves from 12 to 14 ft--lb (16 to 18 N--m) when in-
stalling them into m anifold.
NOTE: Check valves CV3 and CV4 are not used in the
ProPass 200 hydraulic system.
Refer to Hydraulic Schematics in this chapter for circuit
location of check valves.
Orifice Service
The control manifold includes four (4) orifice fittings that
thread into specific manifold ports. Access to these ori-
fice plugs requires removal of the manifold plug. Orifice
locationsareshowninFigure38.
NOTE: Orifice fitting ORF3 is not used in the ProPass
200 hydraulic system.
Refer to Hydraulic Schematics in this chapter for circuit
location of the orifice fittings.
Figure 37
1. Check valve CV1
2. Check valve CV2
3. Check valve CV3
4. Check valve CV4
2
1
3
4
Figure 38
1. Orifice ORF1 (0.040)
2. Orifice ORF2 (0.020)
3. Orifice ORF3 (0.068) 4. Orifice ORF4 (0.020)
3
4
2