Setup Instructions

Page 11
Figure 33: Routing hydraulic hoses
Figure 34: Hydraulic line clamps
I
MPORTANT: When routing either the hydraulic hoses
or the electrical wiring harness always remember to
route them out of the way of all moving components
and always ensure that there is no stress on the line.
This may require loosening and repositioning the
hydraulic hose at the front bulkhead. Refer to Figure
35.
Figure 35: Route hydraulic hose away from
other components
24. Between the front and center hose clamp ensure that
the hose bends upwards to clear the Workman’s
engine. To do this, install a cable tie around the
pressure and return hoses and attach it to one of the
ProPass’ side rail mounting holes. When attaching
the hose, ensure that there is proper tension on the
hoses. Refer to Figure 36.
Figure 36: Ensure proper tension of hydraulic hoses
25. Route and connect the male electrical power plug to
the Electrical Connection Kit.
Note: If the electrical connection kit is installed at
the rear of the tow vehicle, route and secure the
electrical power cord to the hydraulic pressure and
return hoses from the front to the rear of the ProPass.
26. Remove the lift cylinder safety bar and lower the
ProPass back down onto the chassis of the Workman.
27. Insert the pressure and return hoses into the proper
hydraulic port at the rear of the Workman.
28. Install the option and connect the hydraulic hoses to
the ProPass.