TractionCircuitProblems(GreensPro1260)
Problem
PossibleCauseCorrectiveAction
Thehydraulicuidisverycold.Allowthehydraulicuidtowarmby
safelyoperatingthemachineatrest.
Thehydraulicuidlevelinthehydraulic
tankislow.
Adjustthehydraulicuidlevel.
Thehydraulicpumptow(bypass)valve
isopenordamaged.
Closeorreplacethehydraulicpump
bypassvalve.
Thechargepressureislow.
Verifychargepressure;referto
HydraulicPumpChargePressureT est
inChapter5HydraulicSystem.
Oneormoreoriceorscreeninthe
hydraulicpumpispartiallyobstructed
ordamaged.
Cleanorrepairthehydraulicpump
passages.
Ahydraulicpumpreliefvalveisleaking
ordamaged.
Verifyhydraulicpumpreliefvalve
operation;refertoHydraulicPump
FlowandReliefPressureTestin
Chapter5HydraulicSystem.
Thehydraulicpumpiswornor
damaged.
Verifyhydraulicpumpoperation;refer
toHydraulicPumpFlowandRelief
PressureT estinChapter5Hydraulic
System.
Thehydraulicdrivemotoriswornor
damaged.
Repairorreplacethehydraulicdrive
motor.
Thetractionresponseissluggish.
Note:Ifatractioncircuitcomponent
hasinternalwearordamage,it
ispossiblethattheothertraction
componentsarealsodamaged.
Themotioncontrollinkageisincorrectly
adjusted,disconnected,binding,or
damaged.
Verifymotioncontroloperationand
repairoradjustasnecessary;refer
toAdjustingtheControlPedalReturn
toNeutralMechanisminChapter5
HydraulicSystem.
Thehydraulicpumpreliefvalvesare
leakingordamaged.
Verifyhydraulicpumpreliefvalve
operation;refertoHydraulicPump
FlowandReliefPressureTestin
Chapter5HydraulicSystem.
Thetractionsystemoperatesinone
directiononly.
Thehydraulicpumpiswornor
damaged.
Verifyhydraulicpumpoperation;refer
toHydraulicPumpFlowandRelief
PressureT estinChapter5Hydraulic
System.
Troubleshooting:TractionCircuitProblems(GreensPro