TestProcedure(continued)
CAUTION
Beforeopeningthehydraulicsystem,pressthemotioncontrol
pedalstoreleasethepressureinthesystemandavoidinjuryfrom
thepressurizedhydraulicuid.
4.Cleanthejunctionofthehydraulichosesandstraightttingsatthehydraulic
pump(Figure22).T agthehosestocorrespondwiththepumpports(Aand
B)thendisconnectthehosesfromthettings.Plugthehosestoprevent
contaminationfromenteringthesystem.
g274728
Figure22
1.Hydraulicpump
4.PumpBport(travelleft)
2.Chargecircuittestport
5.Pressuregauge0to500psi
3.PumpAport(travelright)
6.Pressuregauge0to5000psi
5.RemovethehydraulicttingfromthehydraulicpumpBport.PlugpumpB
portwitha#8SAEhydraulicplug.
6.Removetheplugfromthechargecircuittestportandinstallamaletest
connector.
7.Installa#8ORFSelbowandamaletestconnectortothehydraulicpumpA
port.