Operator's Manual

DriveSystem
Maintenance
HydraulicSystemSafety
Seekimmediatemedicalattentionifuidisinjected
intoskin.Injecteduidmustbesurgicallyremoved
withinafewhoursbyadoctor.
Ensurethatallhydraulic-uidhosesandlinesare
ingoodconditionandallhydraulicconnections
andttingsaretightbeforeapplyingpressureto
thehydraulicsystem.
Keepyourbodyandhandsawayfrompinhole
leaksornozzlesthatejecthigh-pressurehydraulic
uid.
Usecardboardorpapertondhydraulicleaks.
Safelyrelieveallpressureinthehydraulicsystem
beforeperforminganyworkonthehydraulic
system.
ChangingtheHydraulic
FluidandFilter
ServiceInterval:Aftertherst20hours—Change
thehydraulicuidandlter.
Every400hours—Changethehydraulicuid
andlter.
Important:UseonlyToroPremiumAllSeason
HydraulicFluid(ISOVG46)oranequivalentuid.
Otheruidscouldcausesystemdamage.
1.Placeadrainpanunderthehydraulic-tank
drainplug
(Figure35).
g036888
Figure35
1.Drainplug
2.Removethedrainplugfromthebottomofthe
tank(Figure35).
3.Whentheuidhasdrainedcompletely,install
thedrainplug.
4.Cleantheareaaroundtheltermountingarea.
5.Placeadrainpanunderthelterandremove
thelter(Figure36).
g036797
Figure36
1.Hydrauliclter
6.Fillthereplacementlterwiththeappropriate
hydraulicuid.
30